background image

 

SC2500 User Guide Ver 2.1 

May 6, 2003 

Page 26 of 26 

8. Appendix 

8.1 Contact Information 

For Technical Support or Warranty Repair information, please contact 
Memtech at: 
 
7628 Las Positas Road 
Livermore, CA 94550 U.S.A. 
Phone:  (925) 294-8483 
Fax:  (925) 294-5920 
Email:  

[email protected]

 

 

8.2  SCSI specification information 

Information regarding the SCSI-II specification may be obtained from 
the following locations: 
 
Global Engineering 
15 Inverness Way East 
Englewood, Co. 80112-5704 
Phone: (303) 792-2181 or (800) 854-7179 
Fax: (303) 792-2192 
 

8.3  Limited Lifetime Warranty 

Memtech SSD Corporation (Memtech) warrants your SC2500 against 
defects in material and workmanship for the life of the drive.  The 
warranty is void in the case of misuse, accident, alteration, improper 
installation, misapplication or the result of unauthorized service or 
repair. 
 
The implied warranties of merchantability and fitness for a particular 
purpose, and all other warranties, expressed or implied, except as set 
forth in this warranty, shall not apply to the products delivered. 
 
In no event shall Memtech be liable for any lost profits, lost savings or 
other incidental or consequential damages arising out of the use of, or 
inability to use, this product. 
 
BEFORE RETURNING PRODUCT, A RETURN MATERIAL 
AUTHORIZATION (RMA) MUST BE OBTAINED FROM MEMTECH. 
 
Product shall be returned to Memtech with shipping prepaid.  If the 
product fails to conform and warranty repair is necessary, Memtech 
will reimburse customer for the transportation charges incurred. 

 

Содержание SC2500 Stinger

Страница 1: ...SC2500 Stinger 2 5 Solid State SCSI Drive User Guide 153866 001 Revision 2 1 May 6 2003 Memtech SSD Corporation 7628 Las Positas Road Livermore CA 94550 800 445 5511 www memtech com...

Страница 2: ...chments 21 5 4 Software Installation Procedure 21 6 JUMPER CONFIGURATION 22 6 1 Switch Locations 22 6 2 Default Jumper Configuration 23 6 3 SCSI ID Selection 23 6 4 Write Protection 23 6 5 Termination...

Страница 3: ...perate It is essentially a drop in replacement for standard rotating media The SC2500 can be used in applications where operating conditions are harsh and when reliability is critical A 100 CMOS logic...

Страница 4: ...nds and several optional commands to enhance functionality The following is a list of commands and their equivalent hexadecimal representation 1 Test Unit Ready 00h M 2 Rezero Unit 01h O 3 Request Sen...

Страница 5: ...s a 50 pin right angle 2mm center connector mounted on the PCB to create both a power and signal connection to the host Maximum cable length is 6 meters The diagram below depicts connector orientation...

Страница 6: ...16 DB5 17 KEY 18 DB6 19 GROUND 20 DB7 21 GROUND 22 DBP 23 GROUND 24 TERMPWR 25 ATN 26 BSY 27 GROUND 28 ACK 29 RST 30 MSG 31 GROUND 32 SEL 33 IO 34 C D 35 GROUND 36 REQ 37 GROUND 38 GROUND 39 5 Volt Po...

Страница 7: ...rational or is in a state such that an initiator action is required to make the unit ready the target shall return CHECK CONDITION status with a sense key of NOT READY 3 3 2 Rezero Unit Command 01h Re...

Страница 8: ...riptor block b An unrecovered parity error is detected on the data bus c A target malfunction prevents return of the sense data If a recovered error occurs during the execution of the REQUEST SENSE co...

Страница 9: ...SC2500 User Guide Ver 2 1 May 6 2003 Page 9 of 26 Sense data format...

Страница 10: ...e logical unit is reserved or any extent reservation from any initiator is active in the specified logical unit During the execution of the FORMAT UNIT command the SC2500 may perform a medium defect m...

Страница 11: ...fer length of zero indicates that 256 logical blocks shall be transferred Any other value indicates the number of logical blocks that shall be transferred 3 3 6 Write 6 Command 0Ah The WRITE 6 command...

Страница 12: ...EVPD bit of zero specifies that the SC2500 return the standard INQUIRY data If the page code field is not zero the target shall return CHECK CONDITION status with the sense key set to ILLEGAL REQUEST...

Страница 13: ...SC2500 User Guide Ver 2 1 May 6 2003 Page 13 of 26 Standard Inquiry Data Format Please refer to the SCSI specification for further details on the vital product data pages and formats...

Страница 14: ...cal unit or if the extent reservation option is implemented extents within a logical unit Reserve CDB 3 3 9 Release Unit 17h The RELEASE command is used to release a previously reserved logical unit o...

Страница 15: ...MODE SENSE data at the target s discretion A DBD bit of one specifies that the target shall not return any block descriptors in the returned MODE SENSE data The page control PC field defines the type...

Страница 16: ...des a means for the initiator to request information regarding the capacity of the logical unit Read Capacity CDB 3 3 13 Extended Read 10 28h The READ 10 command requests that the target transfer data...

Страница 17: ...SC2500 User Guide Ver 2 1 May 6 2003 Page 17 of 26 3 3 14 Extended Write 10 The WRITE 10 command requests that the SC2500 write the data transferred by the initiator to the medium Write 10 CDB...

Страница 18: ...nd the sense key shall be set to ILLEGAL REQUEST with an additional sense code of INVALID FIELD IN CDB If the ERA bit is zero a transfer length of zero indicates that no blocks shall be erased This co...

Страница 19: ...Data Access time 0 3 msec Environmental Requirements Operating Ambient Temperature Commercial 0o C to 70o C Extended 20o C to 75o C Industrial 40 o C to 85 o C Storage Temperature 55o C to 125o C Ambi...

Страница 20: ...hat the system disk be addressed as device 0 or 1 on the SCSI bus If a different ID is required refer to section 6 for proper switch settings 5 2 2 Power off the computer system by throwing the main p...

Страница 21: ...able is keyed and cannot be inserted backwards At this point installation is complete 5 2 10 Reattach the AC power cable to the system and power up 5 3 Power and Cable Attachments The following diagra...

Страница 22: ...N 6 1 Switch Locations The following diagram shows the unit as viewed from the bottom and shows the relative location of the switches and jumpers as described in the text below LED CR2 WP ID2 ID1 ID0...

Страница 23: ...ON ON SCSI ID 7 ON ON OFF SCSI ID 6 ON OFF ON SCSI ID 5 ON OFF OFF SCSI ID 4 OFF ON ON SCSI ID 3 OFF ON OFF SCSI ID 2 OFF OFF ON SCSI ID 1 OFF OFF OFF SCSI ID 0 6 4 Write Protection The WP switch of...

Страница 24: ...list of possible error indicators or messages what they indicate and possible solutions to the source problem If no solution is found contact the factory for further assistance 7 1 Error Blink Codes...

Страница 25: ...te protected 3 Remap Table disabled SW1 7 ON 7 3 Unit does not respond to SCSI commands If the unit passes power up diagnostics but does not respond to SCSI commands there may be a SCSI ID contention...

Страница 26: ...p for the life of the drive The warranty is void in the case of misuse accident alteration improper installation misapplication or the result of unauthorized service or repair The implied warranties o...