![Memsic AHRS380ZA-200 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/memsic/ahrs380za-200/ahrs380za-200_user-manual_1770428069.webp)
DMU380ZA Series
User’s Manual
________________________________________________________________________
Doc# 7430-3810 Rev.02
Page 61
[360°/2^16]
[°]
2
pitchAngle
I2
2*pi/2^16
[360°/2^16]
Radians
[°]
Pitch angle
4
yawAngleTrue
I2
2*pi/2^16
[360°/2^16]
Radians
[°]
Yaw angle (true north)
6
xRateCorrected
I2
7*pi/2^16
[1260°/2^16]
rad/s
[°/sec]
X angular rate corrected
8
yRateCorrected
I2
7*pi/2^16
[1260°/2^16]
rad/s
[°/sec]
Y angular rate corrected
10
zRateCorrected
I2
7*pi/2^16
[1260°/2^16]
rad/s
[°/sec]
Z angular rate corrected
12
xAccel
I2
20/2^16
g
X accelerometer
14
yAccel
I2
20/2^16
g
Y accelerometer
16
zAccel
I2
20/2^16
g
Z accelerometer
18
nVel
I2
512/2^16
m/s
North velocity
20
eVel
I2
512/2^16
m/s
East velocity
22
dVel
I2
512/2^16
m/s
Down velocity
24
longitudeGPS
I4
2*pi/2^32
[360°/2^32]
Radians
[°]
GPS Longitude
28
latitudeGPS
I4
2*pi/2^32
[360°/2^32]
Radians
[°]
GPS Latitude
32
altitudeGPS
I2*
2^14/2^16
m
GPS altitude [-100,16284)
34
xRateTemp
I2
200/2^16
deg C
X rate sensor temperature
36
timeITOW
U4
1
ms
DMU ITOW (sync to GPS)
Not Implemented
40
BITstatus
U2
-
-
Master BIT and Status