Screw
regulator onto
gas cylinder
Page 10
Assembly step 7
M6 x 10
Bolt (E)
To check patio heaters for leaks
To be performed in a well ventilated area. Lie heater down on the floor as shown
below. Confirm all control knobs are in the off position. Open the gas control
valve on the bottle or regulator.
Check for leaks by brushing a solution of 1/2 water and 1/2 soap over the gas
system joints as shown in the hose connection and regulator connection.
NEVER USE AN OPEN FLAME to test for leaks at any time.
If bubbles form over any of the joints, there is a leak. Turn off gas supply and
re-tighten all joints.
Repeat test. If bubbles form again, do not use the patio heater. Please contact
your local gas dealer for assistance or email the factory [email protected] or phone
678 534 2876. Leak test annually and whenever the gas bottle is removed or
replaced.
When leak test complete secure lantern to top of support pole with 4 of
the M6x10 bolts (E) and M6 washer.
M6 Washer (G)