The replaceable lubricant cartridge and battery pack.
1.2 The
MEMO
1.2.1 Description
The MEMO regulates the rate of grease output of the
MEMOLUB
®
HPS. It consists of a brass adapter, a black
plastic timing-ring holder, and three plastic timing rings (one
white, one red, and one black). The MEMO is permanently
fitted onto the bearing or other component, and all
MEMOLUB
®
HPS lubricators of any size will recognize its
program setting.
1.2.2 Volumetric Setting of the MEMO
The brass adapter is an extension of the MEMOLUB's
pump cylinder. One end has a short 1⁄4” NPT thread
used to mount the MEMO on the bearing. The other
end is an M12x1.50 thread that screws into the
MEMOLUB
®
lubricator. A set of special stroke-
limiting washers is supplied with each MEMOLUB
®
for use in programming the volume of lubricant
ejected on each output cycle.
When the MEMO is used without washers (yielding full piston stroke), the output volume
at each stroke is 0.635cc. For each washer inserted into the brass adapter of the MEMO,
the output volume will decrease by 0.04cc per stroke. A Maximum of 8 washers
(including a lock washer) can be inserted into the brass adapter. If the stroke-limiting
washers are used, the lock washer should be inserted last to hold the others in place. If
only one washer is used, use the locking washer.
Important Note: When using the 2-Point
Splitter (see Section 3: The 2-Point Splitter), volumetric setting is not possible.
1.2.3 Frequency Setting of the MEMO
The white, red, and black plastic timing rings are used to set
the frequency of ejection cycles of the MEMOLUB
®
HPS.
They are inserted into the black plastic ring-holder either
individually or in combination to obtain the desired frequency
of output cycles.
MEMOLUB
®
HPS User’s Guide
Page
4 of 39
PLI,