Place the cartridge on the pump inlet of the
red housing. Make certain that the
cartridge neck is well seated on the pump
inlet.
•
Place spring and compression plate into
the transparent housing, with the
compression plate facing the housing
opening. Then place the housing
assembly (transparent housing, spring
and compression plate) over the lubric
cartridge which is seated on the red base.
The compression plate should be seated
evenly on the lubricant cartridge.
ant
•
Lock the transparent housing in place with the black locking ring according to
Section 6.2.2
.
6.4 Installing an Oil Cartridge
Installing an oil cartridge is similar to that for grease,
as described in
Section 6.3
, but the oil cartridge
cannot be placed upside down on the red housing
without spilling. First, lift the black rubber seal back
and place the battery pack into the red housing (note:
the Giga model, shown at left, does not use rubber
seal). Insert the identification label, spring, and
compression plate into the transparent housing.
Next, hold the oil cartridge
delicately
in one hand
and place the red housing on the neck of the
cartridge. While holding the oil cartridge firmly on
the red housing, reverse their position. Place the red housing and cartridge on a hard
surface and place transparent housing on top. Lock as instructed in
Section 6.2.2.
6.5 Testing the MEMOLUB
®
HPS (Check Function)
To ensure that the MEMOLUB
®
HPS is working, gently push
on one of the three switches at the bottom of the red housing for
a few seconds. The MEMOLUB
®
HPS will then go through an
ejection cycle. This will confirm that electronics, mechanics and
batteries are okay. It is important that this be done only with a
lubricant cartridge installed. Operating the MEMOLUB
®
HPS
without a cartridge or with an empty cartridge will “un-prime”
the pump (refer to
Section 6.3: Installing a Grease Cartridge
).
MEMOLUB
®
HPS User’s Guide
Page
16 of 39
PLI,
LLC