Memmert IPP 110 - высокоточная термостатическая печь для различных лабораторных приложений. Скачайте бесплатное Руководство по эксплуатации на нашем веб-сайте, чтобы получить подробные инструкции по использованию этого устройства. manualshive.com.
IPP
IPS
OPERATING
INSTRUCTIONS
www.memmert.com | www.atmosafe.net
PELTIER-COOLED INCUBATOR IPP
STORAGE COOLED INCUBATOR IPS
100% ATMOSAFE. MADE IN GERMANY.
Страница 1: ...IPP IPS OPERATING INSTRUCTIONS www memmert com www atmosafe net PELTIER COOLED INCUBATOR IPP STORAGE COOLED INCUBATOR IPS 100 ATMOSAFE MADE IN GERMANY ...
Страница 2: ...fax 49 0 9171 9792 979 E mail service memmert com When contacting customer service always quote the product serial number on the nameplate see page 12 Shipping address for repairs Memmert GmbH Co KG Kundenservice Willi Memmert Str 90 96 DE 91186 Büchenbach Germany Please contact our customer service before sending appliances for repair or before returning equipment otherwise we have to refuse acce...
Страница 3: ... this is indicated at the relevant points in this manual Due to individual configurations and sizes illustrations in this manual may be slightly dif ferent from the actual appearance Function and operation are identical Other documents that have to be observed For operation of the appliance with MEMMERT AtmoCONTROL observe the separate software manual For service and repair work see page 38 observ...
Страница 4: ...et interface 12 2 6 Designation nameplate 12 2 7 Technical data 13 2 8 Ambient conditions 14 2 9 Scope of delivery 14 2 10 Optional accessories 14 3 Delivery transport and setting up 15 3 1 Safety regulations 15 3 2 Delivery 15 3 3 Transport 15 3 4 Unpacking 15 3 4 1 Checking for completeness and transport damage 15 3 4 2 Disposing of packaging material 15 3 5 Storage after delivery 16 3 6 Setting...
Страница 5: ... 27 7 1 Overview 27 7 2 Basic operation in menu mode using the example of language selection 28 7 3 Setup 29 7 3 1 IP address 29 7 3 2 Unit 30 7 3 3 Temperature monitoring Alarm Temp 31 7 3 4 Timer mode 32 7 3 5 Balance only for model sizes 260 and 750 33 7 4 Date and time 34 7 5 Adjustment 35 8 Maintenance and service 38 8 1 Cleaning 38 8 1 1 Working chamber and metal surfaces 38 8 1 2 Plastic pa...
Страница 6: ... you or somebody else could be injured if you do not observe the accompanying safety regulation Caution is used for information that is important for avoiding damage 1 1 2 Signs used Warning signs warning of a danger Danger of electro cution Danger of explosion Dangerous gases vapours Danger of toppling over Prohibition signs forbidding an action Do not lift Do not tilt Do not enter Regulation sig...
Страница 7: ...able load poisonous or explosive vapours or gases may be produced This could cause the appliance to explode and persons could be severely injured or poi soned The appliance may only be loaded with materials test objects which do not form any toxic or explosive vapours when heated up see also chapter Intended use on page 8 Warning In case of appliances of a certain size you can get accidentally loc...
Страница 8: ...ature range of 0 to 70 C Cooled storage incubators IPS are intended for the storage and cooling of substances and samples and for determination of life expectancy at constant temperatures in a range of 14 to 45 C Any other use could be dangerous The appliance is not explosion proof does not comply with the German workplace health safety regulation VBG 24 The appliance may only be loaded with mater...
Страница 9: ... or damage immediately take the appliance out of service and inform your superior You can find information on eliminating malfunctions from page 25 1 8 Switching off the appliance in an emergency Press the main switch at the ControlCOCKPIT Fig 1 This disconnects the appliance from the power supply at all poles ON O O ON N N N O ON O Fig 1 Switch off the appliance by pressing the main switch ...
Страница 10: ... TEMP C Set 37 0 TIMER 30m 04h Ende 23 Nov 13 30 LICHT 100 Fig 2 Construction 1 ControlCOCKPIT with capacitive function keys and LCD displays see page 20 2 On Off switch see page 18 3 Chamber fan 4 Steel grid 5 Interior 6 Nameplate see page 12 7 Door handle see page 19 8 Turn control with confirmation key ...
Страница 11: ...pliance must be carefully checked for chemical compatibil ity with the materials mentioned A material resistance table can be requested from the manufacturer 2 4 Electrical equipment Operating voltage and current consumption See nameplate Protection class 1 i e operating insulation with PE conductor in accordance with EN 61010 Protection type IP 20 acc to EN 60 529 Interference suppression acc to ...
Страница 12: ...e directly connected to a computer laptop see Optional accesso ries on page 14 2 6 Designation nameplate The nameplate Fig 4 provides information about the appliance model manufacturer and technical data It is attached to the front of the appliance on the right behind the door see page 10 Typ IPP 260 F Nr 0109 0088 230 V 2 3 A 50 60 Hz 525 W DIN12880 Kl 3 1 Nenntemp 70 C 1 2 3 4 5 6 10 8 9 7 Fig 4...
Страница 13: ...20 400 480 800 1200 800 1200 Chamber depth C1 mm 250 330 400 500 600 500 600 Chamber volume litres 32 53 108 256 749 256 749 Weight kg 42 53 84 115 211 110 193 Power W 214 240 350 525 1050 350 350 Current consumption A 1 0 1 1 1 6 2 3 4 6 1 6 1 6 max number of sliding shelves 3 4 5 9 14 9 14 max load per sliding shelve kg 30 max load per appliance kg 60 80 100 180 280 180 280 Temperature Adjustmen...
Страница 14: ...iance could lead to sedimentation in the interior and as a consequence could result in short circuits or damage to electrical parts For this reason sufficient measures to prevent large clouds of dust or aggressive vapours from developing should be taken 2 9 Scope of delivery Power cable Sliding grid load capacity 30 kg each The operating instructions at hand Calibration certificate For certain app...
Страница 15: ... on a wooden palette 3 3 Transport The appliance can be transported in three ways With a forklift truck move the forks of the truck entirely under the pallet On a manual pallet jack On its own castors in case of the corresponding configuration for which the catch on the front castors must be released 3 4 Unpacking To avoid damage do not unpack the appliance until you reach the installation site Re...
Страница 16: ...the assem bly instructions provided The installation site must be flat and horizontal and must be able to reliably bear the weight of the appliance see Technical data on page 13 Do not place the appliance on a flammable surface Depending on the model see nameplate a 230 V or 115 V power connection must be available at the installation site The distance between the wall and the rear of the applianc...
Страница 17: ...55 110 260 750 Floor Table Check the load capacity first Stacked Two appliances maximum mounting material feet pro vided Wall mounting Separately packaged fastening material is included in the scope of delivery Observe the assem bly instructions provided Base With without castors Castor frame Height adjustable feet ...
Страница 18: ...e 13 Plug the provided power cable into the rear of the ap pliance and connect it to the power supply Fig 8 4 2 Switching on Switch on the appliance by pressing the main switch on the front of the appliance Fig 9 If the appliance has never been operated before you will be prompted to set the operating lan guage date and time when you first switch it on A description of how to do this is given from...
Страница 19: ... completely B To close the door push the door handle back C A C B Fig 10 Opening and closing the door Warning In case of appliances of a certain size you can get accidentally locked in which is life threatening Do not climb into the appliance 5 3 Loading the appliance Warning When loading the appliance with an unsuitable load poisonous or explosive vapours or gases may be produced This could cause...
Страница 20: ...ing messages are displayed e g if the temperature is exceed ed ON O O ON N N N O ON O End 14 45 44h 44m ON O O ON N N N O ON O LÜFTER 0 C 22 4 TEMP C Set 37 0 3 1 2 9 10 4 5 6 TIMER 30m 04h End 23 Nov 13 30 7 8 LIGHT 100 Fig 12 ControlCOCKPIT of Peltier cooled incubators IPP in operating mode ON O O ON N N N O ON O TIMER End 14 45 44h 44m 180 4 C TEMP Set 180 4 C ON O O ON N N N O ON O LÜFTER 0 C ...
Страница 21: ... or confirmed for approx 30 seconds the appliance automatically restores the former values If you want to cancel the setting procedure press the activation key on the left or right of the display that you want to exit The appliance restores the former values Only the settings that you have confirmed by pressing the confirmation key before cancelling the setting pro cedure are accepted 5 4 3 Adjust...
Страница 22: ...e font and the ap proximate end time in a smaller font beneath TIMER 30m 04h End 23 Nov 13 30 4 Now as described under 5 4 2 set the temperature you want the appliance to oper ate at The set value can be changed at any time while the timer elapses The changes are effective immediately In Setup you can choose if the timer should run setpoint dependent or not This determines whether the timer should...
Страница 23: ...age 31 The setting made applies to all operating modes If the manually set monitoring temperature is exceeded temperature monitoring takes over temperature control and begins to regulate the monitoring temperature Fig 14 t C Setting Alarm Temp Set temperature Controller error Emergency operation Fig 14 Schematic diagram of how the electronic temperature monitoring system works 5 5 2 Mechanical tem...
Страница 24: ...oustic signal Information on what to do in this case is provided in the chapter Malfunctions warning and error mes sages on page 25 5 6 Ending operation 1 Switch off active appliance functions turn down the heating 2 Remove the chamber load 3 Switch off the appliance with the main switch Fig 16 4m FEUCHTE 30 0 rh Set 30 0 rh 22 0 TEMP C C C 22 4 TEMP C Set 37 0 TIMER 30m 04h Ende 23 Nov 13 30 C TE...
Страница 25: ... see page 12 6 1 Warning messages of the monitoring function Description Cause Action See Temperature alarm and max are displayed C TEMP max Set 38 5 C 38 9 The elec tronic temperature monitoring system has assumed heating control Increase the difference between the monitoring and setpoint tempera ture by either increas ing the monitoring temperature Alarm Temp in the setup or decreasing the setpo...
Страница 26: ...ng mode Change to operating or menu mode by pressing the MENU key Error message in timer display Error 23 Pt100 Error Contact Service Appliance error Contact customer service page 2 6 3 Power failure In case of a power failure the appliance operates as follows In normal operation After power supply has been restored operation is continued with the parameters set The time and duration of the power ...
Страница 27: ...epted by pressing the confirmation key are saved 7 1 Overview Press the MENU key to change between the displays in menu mode SETUP SIGNALTÖNE ADJUST LANGUAGE DATE AND TIME 1 2 3 4 5 6 7 8 9 10 11 Fig 17 ControlCOCKPIT in menu mode 1 Language selection activation key 2 Language selection display 3 Date and time display 4 Date and time setting activation key 5 Exit menu mode and return to operating ...
Страница 28: ... the ex ample to the right Deutsch German is highlighted in colour and indicated by a check mark English Deutsch Español Français If you want to interrupt our cancel your settings again press the activation key which you have used to activate the display The appliance returns to the menu overview Only the settings that you have confirmed by pressing the confirmation key before cancelling the setti...
Страница 29: ...s Ethernet interface for connec tion to a network the Unit of the temperature display C or F see page 30 the trigger temperature of the monitoring function Alarm Temp see page 31 the Timer mode see page 32 7 3 1 IP address If you want to operate one ore more appliances in a network each appliance must have its own unique IP address for identification By default each appliance is delivered with the...
Страница 30: ...of the IP address are automatically selected Setting these is done with the turn control according to the descrip tion above Unit IP address 255 168 100 100 Subnetmask 255 255 0 0 Alarm Temp C F 24 Timer Mode 5 After setting the last three digits ac cept the new IP address by pressing the confirmation key The selection returns to the overview The subnet mask is set accordingly SETUP Unit IP addres...
Страница 31: ... to 3 K 1 Activate the SETUP display and select Alarm Temp with the turn control Unit IP address 255 145 136 225 Subnetmask 255 255 0 0 Alarm Temp C F 24 Timer Mode 2 Accept the selection by pressing the confirmation key The current settings are automatically highlighted Unit IP address 255 145 136 225 Subnetmask 255 255 0 0 Alarm Temp C F 24 Timer Mode 3 With the turn control select the de sired ...
Страница 32: ...ed Setting 1 Activate the SETUP display and select Timer Mode with the turn control Unit IP address 255 145 136 225 Subnetmask 255 255 0 0 Alarm Temp C F 38 Timer Mode 2 Accept the selection by pressing the confirmation key The adjustment op tions are automatically highlighted Unit IP address 255 145 136 225 Subnetmask 255 255 0 0 Alarm Temp C F 38 Timer Mode 3 With the turn control select the de ...
Страница 33: ...lower heat output 20 lower heat output 30 Fig 20 Heat output distribution example The 20 left setting causes the lower heating groups to emit 20 less heat than the upper ones The 30 right setting causes the lower heating groups to emit 30 more heat than the upper ones The 0 setting restores the default heat output distribution Setting 1 Activate the SETUP display and select Balance with the turn c...
Страница 34: ...te automatically highlighted On the right the current settings are shown DATE AND TIME Time Time zone Daylight savings 12 05 2012 12 00 GMT 01 Date If you want to change another setting e g the time zone Turn the turn control until the corresponding entry is highlighted Time Daylight savings 12 05 2012 12 00 GMT 01 Date Time zone 2 Accept the selection by pressing the confirmation key The first va...
Страница 35: ...are temperature calibrated and adjusted at the factory In case readjust ment should be necessary later on for example due to influence of the chamber load the appliance can be calibrated customer specifically using three calibration tempera tures of your choice CAL1 Temperature calibration at low temperature CAL2 Temperature calibration at medium temperature CAL3 Temperature calibration at high te...
Страница 36: ...ur letzte Justierung 12 10 2012 12 00 40 0 C K 0 2 C K 0 1 C K 0 2 ADJUST Last adjustment 12 10 2012 12 00 Cal1 Cal2 Cal3 20 0 37 0 5 0 Temperature 2 Press the confirmation key repeatedly until the calibration temperature CAL2 is selected C K 0 2 C K 0 1 C K 0 2 Temperature Cal1 Cal2 Cal3 37 0 5 0 20 0 3 With the turn control set the calibra tion temperature CAL2 to 30 C C K 0 2 C K 0 1 C K 0 2 Te...
Страница 37: ...ould display 31 6 C C 30 0 TEMP C Set 30 0 31 6 C 9 In the SETUP adjust the calibration value CAL2 to 1 6 K actual value measured minus setpoint temperature and save the setting by pressing the confirmation key C K 0 2 C K C K 0 2 Temperature Cal1 Cal2 Cal3 37 0 5 0 30 0 1 6 10 After the calibration procedure the temperature measured by the reference instrument should now also be 30 C C 30 0 TEMP ...
Страница 38: ...inless steel housing Rust deposits can lead to an infection of the stainless steel If rust spots should appear on the surface of the working chamber due to impurities the affected area must be immediately cleaned and polished 8 1 2 Plastic parts Do not clean the ControlCOCKPIT and other plastic parts of the appliance with caustic or solvent based cleaning agents 8 1 3 Glass surfaces Glass surfaces...
Страница 39: ...inge screws are not loose 8 3 Repairs and service Warning After removing covers live parts may be exposed You may receive an electric shock if you touch these parts Disconnect the mains plug before removing any covers Any work inside the appliance may only be performed by qualified electricians Repairs and service work are described in a separate service manual ...
Страница 40: ...e Council This appliance has been brought to market after August 13th 2005 in countries which have already integrated this directive into their national laws It may not be disposed of in normal household waste For disposal please contact your dealer or the manufacturer Any appliances that are infected infectious or contaminated with materials hazardous to health are excluded from return Please als...
Страница 41: ...ting 21 IP address 29 L Language selection 28 Lighting 21 Loading the appliance 19 Log memory 26 M Maintenance 38 Malfunctions 9 25 26 Manufacturer 2 Material 11 Mechanical temperature monitoring 23 Menu 27 Menu mode 27 Minimum clearances 16 Monitoring temperature 23 N Nameplate 12 Network 12 29 O Operating 19 Operating mode 20 Operating personnel 7 19 Operating problems 26 Operation 19 P Packagin...
Страница 42: ...42 Index ...
Страница 43: ......
Страница 44: ... Co KG Postfach 1720 D 91107 Schwabach Tel 49 9122 925 0 Fax 49 9122 14585 E Mail sales memmert com facebook com memmert family Die Experten Plattform www atmosafe net Peltier cooled incubator IPP Storage cooled incubator IPS 24 09 2012 D24034 englisch ...