SAFETY HOSE AND REGULATOR
DANGER
Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and
cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
Connecting Regulator to the LP Cylinder
1. Turn all control knobs to the “
OFF
” position.
2. Turn LP cylinder “
OFF
” by turning hand-wheel clockwise to a full stop.
3. Remove the protective cap from LP cylinder valve. Always use cap and strap
supplied with valve.
4. Hold regulator and insert nipple into LP cylinder valve. Hand tighten the
coupling nut. Hold the regulator in a straight line with LP cylinder valve so as
not to cross-thread the connection.
5. Turn the coupling nut clockwise and tighten to a full stop. The regulator will
seal on the back-check feature in the LP cylinder valve, resulting in some
resistance.
NOTE:
If you cannot complete the connection, disconnect regulator and repeat
steps 4 and 5. If you are still unable to complete the connection,
DO NOT USE THIS REGULATOR!
Regulator Flow Limiting Device
If you are experiencing any of the following performance issues, you may have activated the flow limiting feature in your
regulator:
•
Burners not getting hot enough
•
Low or incomplete burner flames
•
Low gas pressure
•
Difficulty lighting all burners or burners not staying lit
Resetting the Regulator Flow Limiting feature
1. With all control knobs and the gas source in the
“OFF”
position.
2. Disconnect the regulator from the LP cylinder.
3. Turn all control knobs to the
“HI”
position, and let stand for 1-3 minutes, allowing all excess gas in the gas manifold
to dissipate.
4. Turn all control knobs to the
“OFF”
position.
5. Reconnect the hose and regulator to the LP cylinder - Do not cross thread the connection. Hand-tighten only.
6. Check all hose connections to ensure that a positive seal has been made.
7. Slowly open the LP cylinder shut-off valve.
NOTE:
If the LP cylinder is opened too quickly, the flow limiting device in the regulator will activate, limiting the flow of
gas from the LP cylinder.
8. Wait approximately 5 seconds for the hose and regulator pressure to stabilize (to prevent the flow limiting device
eature from being re-activated).
9. Start with the middle two control knobs. Push in control knob to start gas flowing, then turn the control knob
counter-clockwise to activate starter.
10. Repeat step 9 for all remaining burners.
NOTE:
Avoid activating the flow limiting feature by following the proper start up and shut down procedures and
performing a complete leak test and safety check to ensure that there are no leaks in the system, and that a positive
connection has been made between the gas source and manifold assembly.
Hold coupling nut
and regulator as
shown for proper
connection to
LP cylinder valve.
Shut off valve
Check
valve
Содержание G70201
Страница 24: ...1 833 454 0864 24...
Страница 28: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 28 2 1 x9 x1 B A A D17 D6 D5 D4 D9 D8 D3 D3 NOTE This side up...
Страница 30: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 30 6 5 x4 B x4 B D2 D8 D4 B1 D5 D5 D4 D8 D9 D9...
Страница 32: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 32 10 9 x2 C B11 B10 B5 B1...
Страница 34: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 34 13 14 X2 X2 x8 D x4 B C3 C3 C1 C2 x8 B...
Страница 35: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 35 15 x8 B...
Страница 36: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 36 16 Tighten the screws C3 C3 B1 B1...
Страница 37: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 37 17 18 x2 E D A N G E R HEAVY LIFT WITH CARE A1 B1 B1 B1 A1 A1 A1 A2 A2...
Страница 38: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 38 19 x4 B D7 D7 D11 D12 D10 D10...
Страница 39: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 39 20 21 NOTE Please perform a leak test before use...
Страница 42: ...1 833 454 0864 42 NOTES...
Страница 43: ...1 833 454 0864 43 NOTES...