2.  Start up and Operation 

 

 
Please ensure that the M-WRG-S ventilation unit has 
been properly installed by an expert, according to the 
assembly instructions and that the exterior of the unit 
is not damaged. The interior and exterior intakes and 
outlets must not be covered or obstructed. 
 
Turn  on  the  M-WRG-S  ventilation  unit  by  switching 
the  Power  ON/OFF  switch  on  the  left  bottom  side  of 
the  unit  to  ON  and  select  a  ventilation  rate  with  the 
alongside positioned 3-level switch.  
 
 
To ensure a well ventilated and healthy room climate 
it  is  recommended  to  run  the  M-WRG-S  ventilation 
unit  continuously  at  ventilation  level  I  or  II.    If 
needed,  switch  for  a  limited  period  of  time  to 
ventilation level III. 
 
During  the  winter  season,  it  is  recommended  to 
ventilate  the  room  once  daily  for  10  minutes  at  the 
highest  ventilation  rate  (III),  in  order  to  avoid  any 
condensate  buildup  inside  the  M-WRG-S  ventilation 
unit.    
 
Caution:  Before  turning  off  the  M-WRG-S  ventilation 
unit  while  exterior  temperatures  are  below  0°C,  the  
unit  has  to  be  run  for  a  minimum  of  10  minutes  at 
level III for antifreeze protection. 
 
 
 
Air flaps: 
The air flaps will be automatically opened or closed if 
the M-WRG-S ventilation unit is switched ON or OFF. 
In case of a malfunction make sure the flaps are not 
blocked and repeat once again to switch the unit ON 
or  OFF.  In  case  of  a  power  outage  the  air  flaps  will 
be closed automatically 
 
 
 
After  the  M-WRG-S  ventilation  unit  is  switched 
OFF,  please  wait  a  minimum  of  15  seconds 
before switching it ON again. 
 
 
 
 
 

 

 

 

 

 

 

Flaps closed 

Flaps open 

AUS 
EIN
 

15m³/h 
30m³/h 
60m³/h 

Содержание M-WRG-S

Страница 1: ...Best Nr 5302 00 01 03 2011 USER MANUAL HOME VENTILATION WITH HEAT RECOVERY Ventilation Unit M WRG S ...

Страница 2: ...we advise to be cautious especially during the summer season and warm weather due to the fact that the moisture in the air will condense on cold interior walls and despite ventilation moisture damages can occur Therefore only ventilate at night during warm weather seasons If you would like to ventilate such rooms with a M WRG ventilation system please consult with the manufacturer prior to purchas...

Страница 3: ... S ventilation unit overview 6 2 Start up and Operation 7 3 Filter Replacement 8 3 1 Filter selection 8 3 2 Replacement of Filters 8 3 2 1 Remove unit cover 8 3 2 2 Remove old Filters 9 3 2 3 Insert new Filters 9 3 2 4 Put back on cover 10 4 Cleaning the M WRG S ventilation unit 10 5 Trouble shooting 11 6 Antifreeze Protection 11 7 Technical Data 12 ...

Страница 4: ...in It is not suitable for drying a building during construction or to ventilate a building while interior renovations are in progress A continuously high concentration of dust and or moisture will clog the filters additionally and overwork the automated extraction of condensate Never operate the M WRG S ventilation unit without the suitable filters The filters protect your health and your living s...

Страница 5: ...fresh air from the exterior As the air streams move through the air ducts of the heat exchanger core heat is transferred from the warm passage to the cold while the airstreams are never combined The cooled stale air is led out and the pre tempered fresh air then streams into the room without causing a draft Interior Stale Air Intake Supply Air Outlet Exterior Fresh Air Intake Exhaust Air Outlet St...

Страница 6: ... overview Casing Cover Dual switch Power switch ON OFF 3 level switch for Ventilation Rate Supply Air Outlet Stale Air Intake Ring Cover for Stale Air Filter Cover for Supply Air Filter Facade Cover Ventilation Hood Fresh Air Intake Exhaust Air Outlet ...

Страница 7: ... time to ventilation level III During the winter season it is recommended to ventilate the room once daily for 10 minutes at the highest ventilation rate III in order to avoid any condensate buildup inside the M WRG S ventilation unit Caution Before turning off the M WRG S ventilation unit while exterior temperatures are below 0 C the unit has to be run for a minimum of 10 minutes at level III for...

Страница 8: ...e Activated Carbon Filter F6 only needed for supply air Only use original filters from Meltem Otherwise Meltem cannot guarantee a smooth operation and may not be held liable for any malfunctions Replacement filters can be ordered at your local HVAC supplier or at www meltem com 3 2 Replacement of Filters No tools are required for filter replacement Both filters should be replaced at the same time ...

Страница 9: ...r covers making sure the marked arrows on case and cover are aligned and turn right The marking arrow on the cap has to align with the marking on the M WRG S ventilation unit Make sure the covers sit flat and tight on the cover Repeat this process for both supply and stale air filter caps Note Allergy Filter or Activated Carbon Filter need to be installed for the supply air only on the right side ...

Страница 10: ...l the hooks on each side snap into place Turn the M WRG S ventilation unit back on with the power switch 4 Cleaning the M WRG S ventilation unit The M WRG S ventilation unit is made of high quality synthetic material and only needs little cleaning From time to time we recommend to clean the surface of the unit with a damp cloth In order to preserve the parts we recommend only to use mild cleaning ...

Страница 11: ...l section filter replacement M WRG S ventilation unit starts to beep in intervals The M WRG S ventilation unit signals a soon to be done filter replacement Replace the filters see User Manual section filter replacement 6 Antifreeze Protection The M WRG S ventilation unit is equipped with an antifreeze protection In case of very low exterior temperatures the M WRG S ventilation unit will automatica...

Страница 12: ...evel Lp in dB A 10 m concealed installation 15 5 24 36 Noise level Lp in dB A 10 m wall mounted 19 24 35 Weight kg approx 8 1 Air duct diameter mm 100 Ventilation unit dimensions Wx H x D in mm 409 x 388 x 196 Filter class filter surface in m Standard filter G4 0 36 Allergy filter optional F 7 0 32 Activated carbon filter optional F 6 0 12 Fully automatic air flap control even during blackouts yes...

Отзывы: