background image

M-WRG-S 

User Manual 

 

 

 
 

 
 

 

 

- 4 - 

 

 

1.  You have made the right choice!  

 
 

With  the  M-WRG-S  decentralized  ventilation  unit  with  heat  recovery,  you  acquired  a  high  quality  product.  
M-WRG-S  stands  for  Meltem  –  heat  recovery  –  with  comfort.  Meltem‘s  „know  how“  of  more  than  30  years 
developing and producing  decentralized ventilation systems is now combined with their innovate heat recovery 
process. 
Ventilation  by  opening  windows  especially  during  cold  seasons,  belong  to  the  past.  From  now  on,  fresh  and 
filtered air is supplied fully automated. The stale air is extracted from your home and while passing through the 
heat  exchanger  its  warmth  is  transferred  to  the  fresh  air.  While  doing  so,  the  M-WRG  units  have  a  minimum 
power  consumption.  You  save  heating  costs,  increase  the  comfort  of  your  home  and  at  the  same  time  reduce 
the impact on the environment by reducing CO2 emissions. 
The  system  is  constructed  for  continuous  operation.  We  guarantee  an  effective  operation  as  well  as  a  long 
lifespan of the system if it is correctly used. We hope you will enjoy your new M-WRG home ventilation system 
with heat recovery! 
 

1.1  Safety and Security 

 

 

 

The M-WRG-S ventilation unit may only be operated once installed correctly. 

 

 

For correct installation of the system please follow the instructions of the assembly manual. 

 

 

The  M-WRG-S  ventilation  unit  may  only  be  used  for  the  ventilation  of  living  space  and  interior  rooms 

(Kitchens, bathrooms, basements, offices, etc). With rooms that have an excessive build up of dust and 
corrosive gas emissions, the M-WRG-S ventilation unit may be limited and/or damaged in its operating 
capacity. 

 

 

Please familiarize yourself with the operating modes and procedures of the M-WRG-S ventilation unit. 

 

 

The M-WRG-S ventilation unit is especially suitable for the drying phase after the building is constructed 

and  the  inhabitants  have  moved  in.  It  is  not  suitable  for  drying  a  building  during  construction  or  to 
ventilate a building while interior renovations are in progress. A continuously high concentration of dust 
and/or moisture will clog the filters additionally and overwork the automated extraction of condensate. 

 

 

Never  operate  the  M-WRG-S  ventilation  unit  without  the  suitable  filters.  The  filters  protect  your  health 

and your living space from exterior environmental influences. Only with the suitable filters, the M-WRG-S 
ventilation unit will remain clean. Additionally it will prevent the pollution of the electrical components and 
the heat converter, as well as reduce or prevent full operating capacity of the M-WRG-S ventilation unit. 

 

 

Do not install the M-WRG-S ventilation unit into the interior of a cabinet or other furniture. Do not cover 

the  M-WRG-S  ventilation  unit  with  a  any  type  of  fabric  (towel,  curtains,  etc.)  or  any  other  objects 
(furniture, blinds, etc.).  

 

 

Please follow the instructions contained in this user manual.  

 

 

Please follow the maintenance instructions contained in this user manual. 

 

 

Important Indication according to DIN EN 60335: This M-WRG-S ventilation unit is not to be operated 

by persons (including children) with limited physical, sensory or mental capabilities, or lack of experience 
and/or  lack  of  knowledge.  Except  if  they  are  supervised,  or  were  given  instructions  how  to  use  the  
M-WRG-S ventilation unit, by a legal guardian responsible for their safety and security. Children should 
be  supervised,  in  order  to  ensure  that  they  are  not  playing  with  the  M-WRG-S  ventilation  unit.  
 

 

If these Safety and Security regulations are not regarded, Meltem will not be held liable!  

Safety Advice for installing the M-WRG-S ventilation unit in rooms with open fire places: For planning and 
installation  of  the  ventilation  system,  the  fireplace  safety  regulations  (i.e.FeuVo)  have  to  be  met!  Before 
operating  the  M-WRG-S  ventilation  unit,  the  fireplace  regulations  have  to  be  discussed  and  approved  by  the 
responsible official authorities and the chimney sweeper.  

Содержание M-WRG-S

Страница 1: ...Best Nr 5302 00 01 03 2011 USER MANUAL HOME VENTILATION WITH HEAT RECOVERY Ventilation Unit M WRG S ...

Страница 2: ...we advise to be cautious especially during the summer season and warm weather due to the fact that the moisture in the air will condense on cold interior walls and despite ventilation moisture damages can occur Therefore only ventilate at night during warm weather seasons If you would like to ventilate such rooms with a M WRG ventilation system please consult with the manufacturer prior to purchas...

Страница 3: ... S ventilation unit overview 6 2 Start up and Operation 7 3 Filter Replacement 8 3 1 Filter selection 8 3 2 Replacement of Filters 8 3 2 1 Remove unit cover 8 3 2 2 Remove old Filters 9 3 2 3 Insert new Filters 9 3 2 4 Put back on cover 10 4 Cleaning the M WRG S ventilation unit 10 5 Trouble shooting 11 6 Antifreeze Protection 11 7 Technical Data 12 ...

Страница 4: ...in It is not suitable for drying a building during construction or to ventilate a building while interior renovations are in progress A continuously high concentration of dust and or moisture will clog the filters additionally and overwork the automated extraction of condensate Never operate the M WRG S ventilation unit without the suitable filters The filters protect your health and your living s...

Страница 5: ...fresh air from the exterior As the air streams move through the air ducts of the heat exchanger core heat is transferred from the warm passage to the cold while the airstreams are never combined The cooled stale air is led out and the pre tempered fresh air then streams into the room without causing a draft Interior Stale Air Intake Supply Air Outlet Exterior Fresh Air Intake Exhaust Air Outlet St...

Страница 6: ... overview Casing Cover Dual switch Power switch ON OFF 3 level switch for Ventilation Rate Supply Air Outlet Stale Air Intake Ring Cover for Stale Air Filter Cover for Supply Air Filter Facade Cover Ventilation Hood Fresh Air Intake Exhaust Air Outlet ...

Страница 7: ... time to ventilation level III During the winter season it is recommended to ventilate the room once daily for 10 minutes at the highest ventilation rate III in order to avoid any condensate buildup inside the M WRG S ventilation unit Caution Before turning off the M WRG S ventilation unit while exterior temperatures are below 0 C the unit has to be run for a minimum of 10 minutes at level III for...

Страница 8: ...e Activated Carbon Filter F6 only needed for supply air Only use original filters from Meltem Otherwise Meltem cannot guarantee a smooth operation and may not be held liable for any malfunctions Replacement filters can be ordered at your local HVAC supplier or at www meltem com 3 2 Replacement of Filters No tools are required for filter replacement Both filters should be replaced at the same time ...

Страница 9: ...r covers making sure the marked arrows on case and cover are aligned and turn right The marking arrow on the cap has to align with the marking on the M WRG S ventilation unit Make sure the covers sit flat and tight on the cover Repeat this process for both supply and stale air filter caps Note Allergy Filter or Activated Carbon Filter need to be installed for the supply air only on the right side ...

Страница 10: ...l the hooks on each side snap into place Turn the M WRG S ventilation unit back on with the power switch 4 Cleaning the M WRG S ventilation unit The M WRG S ventilation unit is made of high quality synthetic material and only needs little cleaning From time to time we recommend to clean the surface of the unit with a damp cloth In order to preserve the parts we recommend only to use mild cleaning ...

Страница 11: ...l section filter replacement M WRG S ventilation unit starts to beep in intervals The M WRG S ventilation unit signals a soon to be done filter replacement Replace the filters see User Manual section filter replacement 6 Antifreeze Protection The M WRG S ventilation unit is equipped with an antifreeze protection In case of very low exterior temperatures the M WRG S ventilation unit will automatica...

Страница 12: ...evel Lp in dB A 10 m concealed installation 15 5 24 36 Noise level Lp in dB A 10 m wall mounted 19 24 35 Weight kg approx 8 1 Air duct diameter mm 100 Ventilation unit dimensions Wx H x D in mm 409 x 388 x 196 Filter class filter surface in m Standard filter G4 0 36 Allergy filter optional F 7 0 32 Activated carbon filter optional F 6 0 12 Fully automatic air flap control even during blackouts yes...