VENTILATION THE RIGHT WAY

V E N T I L AT I O N   &   H E AT   R E C O V E R Y

INST

ALLA

TION MANUAL

HOME VENTILATION WITH HEAT RECOVERY

Outer wall terminals

M-WRG-ES

M-WRG-ESR

M-WRG-ESG/AP

M-WRG-ESG/UP

for fitting on external walls

Part no. 5300-20-01 Week 30/2015 EN

Содержание M-WRG-ES

Страница 1: ...nfo meltem com www meltem com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY INSTALLATION MANUAL HOME VENTILATION WITH HEAT RECOVERY Outer wall terminals M WRG ES M WRG ESR M WRG ESG AP M WRG ESG UP for fitting on external walls Part no 5300 20 01 Week 30 2015 EN ...

Страница 2: ...1 4 1 Outer wall terminal stainless steel pod M WRG ES 11 4 2 Outer wall terminal stainless steel pipe set M WRG ESR 11 4 3 Outer wall terminal stainless steel louvred design M WRG ESG 11 5 Installing the outer wall terminals 12 5 1 Installing the outer wall terminal stainless steel pod M WRG ES 13 5 1 1 Checking the ventilation pipes 13 5 1 2 Drilling the holes for the outer wall terminal 13 5 1 ...

Страница 3: ...e part of the product Keep the instructions in a safe place for future reference WARNING Follow ALL danger and warning instructions and notes on precautionary measures Read section 2 Safety instructions on page 6 carefully 1 2 Description These instructions describe how to install the outer wall terminals M WRG ES M WRG ESR and M WRG ESG on an external wall 1 2 1 Outer wall terminal stainless stee...

Страница 4: ...el louvred design M WRG ESG M WRG ESG UP outer wall terminal stainless steel louvred design flush mount version part no 5161 M WRG ESG UP P outer wall terminal stainless steel louvred design flush mount version white pow der coated part no 5162 M WRG ESG AP outer wall terminal stainless steel louvred design surface mount version part no 5163 M WRG ESG AP P outer wall terminal stainless steel louvr...

Страница 5: ...tempera ture ranges between 0 C and 40 C 1 5 Environmentally friendly disposal The outer wall terminals must not be disposed of in the residual waste bin Dispose of the outer wall terminals in accordance with the electronic waste disposal regulations that apply on site 1 6 Revision index Edition Manual Date 2nd edition Installation manual for outer wall terminals M WRG ES M WRG ESR M WRG ESG Week ...

Страница 6: ...ortant information about the product or about a part of the manual to which particular attention should be paid 2 2 Notes on using the ventilation units safely WARNING Build up of icicles and ice patches at low temperatures The heat recovery process in our ventilation units causes condensation This condensation is dissipated to the outside via the exhaust air pipe When external temperatures drop b...

Страница 7: ...tholz 4 D 82239 Alling info meltem com www meltem com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY For any use contrary to the intended use Meltem Wärmerückgewinnung GmbH Co KG shall accept no liability for any damage that may occur and offers no warranty that the com ponents will work perfectly and correctly ...

Страница 8: ... Quantity 1 Selected outer wall terminal stainless steel pod section 1 2 1 page 3 1x 2 Drilling template 1x 3 Vaseline tube 1x 4 Dowel 6 x 30 mm for fitting to brick wall 6x 5 Screws 4 0 x 40 mm stainless steel 6x Installation manual 1x NOTE The fixing materials supplied are intended for fixing the outer wall terminal to brick walls For other wall structures contact your facade constructor to ensu...

Страница 9: ...GHT WAY VENTILATION HEAT RECOVERY 3 2 Items supplied with the outer wall terminal stainless steel pipe set M WRG ESR Fig 5 Items supplied with the outer wall terminal stainless steel pipe set Item Description Quantity 1 Selected outer wall terminal stainless steel pipe set section 1 2 2 page 4 2x 2 Rosette M WRG ESR RO or M WRG ESR RO P only 2x 3 Vaseline tube 1x Installation manual 1x ...

Страница 10: ...G AP or M WRG ESG AP P only section 1 2 3 page 4 1x 2 Outer wall terminal stainless steel louvred design flush mount M WRG ESG UP or M WRG ESG UP P only section 1 2 3 page 4 1x 3 Drilling template 1x 4 Vaseline tube 1x 5 Dowel 6 x 30 mm for fitting to brick wall 6x 6 Screws 4 0 x 40 mm stainless steel 6x Installation manual 1x NOTE The fixing materials supplied are intended for fixing the outer wa...

Страница 11: ...n brick walls Make sure you use suitable tools for other wall structures Spirit level Torx screwdriver TX20 4 2 Outer wall terminal stainless steel pipe set M WRG ESR Permanently elastic sealant solvent free if applied to polystyrene 4 3 Outer wall terminal stainless steel louvred design M WRG ESG Allen key size 4 Cross head screwdriver Hammer drill with 6 mm masonry bit for fitting the outer wall...

Страница 12: ...in to the outer wall terminals Dust and other soiling can then collect on the grease deposits which will encourage flash rusting see also section 6 Cleaning and care instructions on page 22 Do not remove the protective film from the outer wall terminals until the installation is com plete NOTE The following requirements must be fulfilled before the outer wall terminals are fitted The external wall...

Страница 13: ...uter wall terminal base plate will be damaged 5 1 2 Drilling the holes for the outer wall terminal Press the pre punched cut outs item 1 in Fig 8 for the ventilation pipes out of the drilling template item 2 in Fig 8 Position the drilling template item 2 in Fig 8 correctly on the ventilation pipes and flush with the facade NOTE Note the OBEN TOP item 3 in Fig 8 printed on the drilling template NOT...

Страница 14: ...aling surfaces item 4 in Fig 9 on the inside with Vase line Carefully position the base plate item 1 in Fig 10 correctly on the ventilation pipes Be careful not to damage the seals NOTE Make sure that the drip edge item 2 in Fig 10 is pointing downwards Use a spirit level to align the base plate vertically see item 3 in Fig 10 Use the six screws provided to fix the base plate item 4 in Fig 10 Atta...

Страница 15: ...n Fig 12 NOTE The cut surfaces of the ventilation pipes must be deburred If this is not the case there is a risk that the seals of the outer wall terminal will be dam aged 5 2 2 Applying permanently elastic sealant and Vaseline Apply a thin coating of permanently elastic sealant all around the outside of the ends of the ventilation pipes item 1 in Fig 13 This will fix the outer wall terminal in pl...

Страница 16: ...ter wall terminals item 2 in Fig 15 Place the outer wall terminals on the venti lation pipes Direct the drip edges item 3 in Fig 15 downwards NOTE If the stainless steel pipe does not lie flush against the external wall seal the gap between the stainless steel pipe and the external wall with a bead of permanently elastic sealant There is a risk that the plaster will be damaged if this is not done ...

Страница 17: ...the case there is a risk that the seals on the outer wall terminal base plate will be damaged 5 3 2 Drilling the holes for the outer wall terminal Press the pre punched cut outs item 1 in Fig 17 for the ventilation pipes out of the drilling template item 2 in Fig 17 Position the drilling template item 2 in Fig 17 correctly on the ventilation pipes and flush with the facade NOTE The fixing material...

Страница 18: ...ine Carefully position the base plate item 1 in Fig 19 correctly on the ventilation pipes Be careful not to damage the seals NOTE Make sure that the drip edge item 2 in Fig 19 is pointing downwards Use a spirit level to align the base plate vertically item 3 in Fig 19 Use the six screws provided to fix the base plate item 4 in Fig 19 Correctly position the cover item 1 in Fig 20 on the base plate ...

Страница 19: ...ot the case there is a risk that the seals on the outer wall terminal base plate will be damaged 5 4 2 Drilling the holes for the outer wall terminal Press the pre punched cut outs item 1 in Fig 22 for the ventilation pipes out of the drilling template item 2 in Fig 22 Position the drilling template item 2 in Fig 22 correctly on the ventilation pipes and flush with the facade NOTE The fixing mater...

Страница 20: ...rrectly on the ventilation pipes Be careful not to damage the seals or bend the perforated plates item 2 in Fig 24 The perforated plates fix the base plate in the plaster NOTE Make sure that the drip edge item 3 in Fig 24 is pointing downwards Use a spirit level to align the base plate vertically item 4 in Fig 24 Use the six screws provided to fix the base plate item 5 in Fig 24 Mask the whole fro...

Страница 21: ...com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY Fig 25 Fixing the cover Position the cover item 1 in Fig 25 on the base plate NOTE Make sure that the louvres of the cover are point ing downwards to prevent the ingress of water in driving rain Use the hexagon socket screw to fix the cover item 2 in Fig 25 Clean the outer wall terminal see section 6 on page 22 ...

Страница 22: ...t is already present using a soft lint free cloth and stainless steel cleaner Immediately remove particles of iron metal filings plaster and swarf from the surface of the outer wall terminals Remove lime and cement spatter as quickly as possible before it hardens from the surface of the outer wall terminals Do not use abrasive cleaning utensils pan scourers steel wool etc and do not use clean ing ...

Страница 23: ...l Outer wall terminals M WRG ES M WRG ESR M WRG ESG 23 Meltem Wärmerückgewinnung GmbH Co KG Am Hartholz 4 D 82239 Alling info meltem com www meltem com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY Space for notes ...

Страница 24: ...h the unit described in it There may nevertheless still be differences so we cannot guarantee complete accuracy The information in this publication is regularly checked and any necessary corrections are made in the subsequent edi tions Copyright Meltem Wärmerückgewinnung GmbH Co KG We reserve the right to make changes Meltem Wärmerückgewinnung GmbH Co KG Am Hartholz 4 D 82239 Alling Germany Tel 49...