Installation manual
M-WRG-S...
- 17 -
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L AT I O N & H E AT R E C O V E R Y
9
General installation instructions
NOTE
—
The unit must be installed in accordance with the generally acknowledged rules of tech-
nology.
—
Connections with adjacent components must be formed to absorb movements between
the contact surfaces.
—
Seal any connections that are exposed to driving rain with tapes, profiles or sealants such
that they offer sufficient protection against the expected conditions.
9.1
Surface-mount installation/flush-mount installation
This manual describes the surface-mount and flush-mount installation of the ventilation unit.
—
For
surface-mount installation
, follow the steps in sections „10 Surface-mount installa-
tion“ from page 18 and „11 Installing the ventilation unit“ from page 26.
—
For
flush-mount installation
, follow the steps in section „11 Installing the ventilation unit“
The ventilation unit is installed once the work described in the following installation
manuals is complete:
Installation manual
Part no.
Flush-mount installation kit M-WRG-M (frame construction)
5300-00-01
Flush-mount installation kit with plastering trim (solid construction)
M-WRG-M/MB
5300-01-01
Flush-mount installation kit M-WRG-M/MB-FK...
5300-03-01
Flush-mount installation kit M-WRG-M/MB-FR...
5300-05-01
WARNING
Follow the relevant accident prevention regulations
►
Follow the accident prevention regulations when setting up the installation location.
►
Protect the outside area against falling parts.
9.2
Electrically disconnecting mains cables
During installation, the ventilation unit is connected to the power supply with a mains cable.
DANGER
Potentially fatal voltages.
—
The electrical installation work must only be carried out by a qualified electrician.
—
The VDE regulations or any special safety regulations applicable in your country apply to
the electrical installation work.
►
Disconnect the mains cable for connecting to the ventilation unit on all poles from the
mains supply.
►
Make sure that the mains supply cannot be switched on again.