Step 2.
Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term)
on your host PC with the settings described in
. Once you perform that, you should
get the CLI prompt of the system.
Table 9 - Serial Terminal Program Configuration
Parameter
Setting
Baud Rate
9600 or 115200 (see below)
Data bits
8
Stop bits
1
Parity
None
Flow Control
None
Step 3.
Login as
admin
and use
admin
as password. On the first login, the MLNX-OS configuration
wizard will start.
Step 4.
To configure network attributes and other initial parameters to the system, follow the con-
figuration wizard as shown in
The baud rate is different per CPU type of the system.
The systems based on x86 CPU (SX1400) should be configured with baud rate =
115200, while the rest of the systems (based on PPC460),should be configured with
9600.
Table 10 - Configuration Wizard Session - DHCP
Wizard Session Display
Comments
Mellanox configuration wizard
Do you want to use the wizard
for initial configuration? yes
You must perform this configuration the first time you operate
the system or after resetting the system. Type ‘y’ and then press
<Enter>.
Step 1: Hostname? [switch ]
If you wish to accept the default hostname, press <Enter>. Other-
wise, type a different hostname and press <Enter>.
Step 2: Use DHCP on mgmt0
interface? [no] yes
Perform this step to obtain an IP address for the system. (mgmt0
is the management port of the system).
If you wish the DHCP server to assign the IP address, type ‘yes’
and press <Enter>.
If you type ‘no’ (no DHCP), then you will be asked whether you
wish to use the ‘zeroconf’ configuration or not.
If you enter ‘no’ (no Zeroconf), you must enter a
static
IP, and the
session will continue.
Step 3: Enable IPv6? [yes]
The management interface will be able to use IPv6 addresses.
Step 4: Enable IPv6 auto-con-
fig (SLAAC) on mgmt0 inter-
face? [no]
This turns on auto-configuration of the IPv6 addresses. This is
unsuitable for DHCPv6.
If you enter "no" (no IPv6), you will automatically be referred to
Step 6.
Содержание SX1012
Страница 24: ...Installation Rev 1 4 27 Mellanox Technologies Figure 11 Installation Kit Parts for a Side by Side Installation...
Страница 35: ...Rev 1 4 38 Mellanox Technologies Figure 24 SFP Removal and Insertion Tool...
Страница 54: ...Interfaces Rev 1 4 57 Mellanox Technologies Figure 36 Pull out Tab...
Страница 76: ...Rev 1 4 111 Mellanox Technologies 5 6 45 C 113 F 8 3 7 8 9 10 11 12...
Страница 79: ...Rev 1 4 114 Mellanox Technologies 3 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 PSU InfiniBand...
Страница 92: ...Rev 1 4 127 Mellanox Technologies 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...