![Mellanox Technologies Spectrum SN2410 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/mellanox-technologies/spectrum-sn2410/spectrum-sn2410_hardware-user-manual_1768390039.webp)
Installation
Rev 1.2
Mellanox Technologies
39
Step 5.
Before attempting a remote (for example, SSH) connection to the system, check the mgmt0
interface configuration. Specifically, verify the existence of an IP address. To check the current
mgmt0 configuration, enter the following command:
Step 6.
You are advised to check the software version embedded in your system, using the command
‘show version’. you can continue and compare this version to the latest version that can be
retrieved from Mellanox support site. To upgrade software, simply refer to MLNX-OS user
manual.
2.7.1.3 Remote Connection with MLNX-OS
Once the network attributes are set, you can access the CLI via SSH or the WebUI via HTTP/
HTTPs.
To access the CLI, perform the following steps:
Step 1.
Set up an Ethernet connection between the system and a local network machine using a stan-
dard RJ45 connector.
Step 2.
Start a remote secured shell (SSH) using the command: “ssh -l <username> <IP_address>”,
r-qa-sit-switch01 (config) # show interfaces mgmt0
Interface mgmt0 status:
Comment:
Admin up: yes
Link up: yes
DHCP running: yes
IP address: 192.168.1.100
Netmask: 255.255.255.0
IPv6 enabled: yes
Autoconf enabled: no
Autoconf route: yes
Autoconf privacy: no
DHCPv6 running: no
IPv6 addresses: 1
IPv6 address: fe80::202:c9ff:fe63:b55a/64
Speed: 1000Mb/s (auto)
Duplex: full (auto)
Interface type: ethernet
Interface source: physical
MTU: 1500
HW address: 00:02:C9:63:B5:5A
RX bytes: 968810197 TX bytes: 1172590194
RX packets: 10982099 TX packets: 10921755
RX mcast packets: 0 TX discards: 0
RX discards: 0 TX errors: 0
RX errors: 0 TX overruns: 0
RX overruns: 0 TX carrier: 0
RX frame: 0 TX collisions: 0
TX queue len: 1000
r-qa-sit-switch01 (config) #
# ssh -l <username> <ip_address>
Содержание Spectrum SN2410
Страница 1: ...www mellanox com Mellanox 1U Switch Systems Hardware User Manual Models SN2700 and SN2410 Rev 1 2...
Страница 53: ...Interfaces Rev 1 2 Mellanox Technologies 53 Figure 45 SN2410 Inventory Information Illustration...
Страница 72: ...Mellanox Technologies 72 8 9 10 11 12 13...
Страница 73: ...Rev 1 2 Mellanox Technologies 73 14 15 16 17 18 19...
Страница 75: ...Rev 1 2 Mellanox Technologies 75 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Страница 76: ...Mellanox Technologies 76 10 11 12 13 14 15 16 UL 4mA...
Страница 78: ...Mellanox Technologies 78 23 24 China CCC Warning Statement TN IT...
Страница 91: ...Rev 1 2 Mellanox Technologies 91 7 8 9 10 11 12 13...
Страница 92: ...Mellanox Technologies 92 14 15 16 17 18 UL CSA 19 UL 4 UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...