MELER GLUING SOLUTIONS
4-26
MELTER OPERATION
4. Disconnect the pneumatic power to the applicators and the electrical
power to the control unit programmer, if there is one.
Additional temperature safety signal
The Macro 200 melter is equipped with an additional temperature safety
signal which stops the machine in case of a certain temperature above the
temperature of the premelter is reached. This signal deactivates the main
contactor. This prevents the adhesive and the premelter from damage.
To program this additional safety temperature, follow these steps:
1. Select ‘
Ʋ
1’ mode with the rotating arrow.
2. Select the desired additional safety temperature between 0ºC and
200ºC using the left- right arrows. The additional safety temperature
recommended is 20ºC above the premelter temperature as maximum.
3. Select ‘RUN’ mode with the rotating arrow in order to memorize the
desired value.
Note:
if an error appears on the programmer display, check the temperature
sensor.
v1
1
1
2
2
3
3
Содержание MACRO 200
Страница 1: ...ADHESIVE MELTER MACRO 200 INSTRUCTIONS MANUAL MA 5068 ENG 221220 GLUING SOLUTIONS ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 8 14 13 11 15 1 2 3 7 6 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions Macro 200 1480 1120 875 1825 ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5068 ENG MACRO 200 INSTRUCTIONS MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...