FOCKE MELER GLUING SOLUTIONS
INSTALLATION
3-2
Electrical consumption
In order to install a Macro 200 melter, we should take into consideration
the total consumption of the installation, including the consumption of the
installed hoses and applicators.
Before connecting, make sure that the voltage that is being connected to the
melter is the correct one appearing on the equipment’s characteristics plate.
Connect the machine and check to see if it is well grounded.
Warning:
Risk of electrocution. Even when the equipment is turned off,
voltage remains in the intake terminals, which may be dangerous during
internal equipment manipulations.
Install a power switch for disconnecting the melter equipment from the
electrical network. It must be protected against overload and short circuits by
circuit breaker and install appropriate personal protection leads to mass by
differential switch.
Consumption figures, according to melter and output configuration, are
included in the table in the section ‘Electrical power connection’.
Compressed air
As an option, a pneumatically activated by-pass valve or an air drying system
may be installed. If these are added to the system, a dry, unlubricated
compressed air network must be available, with a maximum pressure of 6 bar.
The by-pass valve consumes next to no air, given that this is a pressurized
closed circuit.
Other factors
While installing Macro 200 melters, other practical considerations should be
kept in mind:
• Keep the load opening accessible for comfortable melter filling.
• Position the melter equipment in such a way that you can easily see the
front panel display where temperatures and possible alarm signals are
shown.
Item
Description
Dimensions
A
DOOR OPENED
795 mm
B
ELECTRICAL CABINET DISPLACEMENT
410 mm
C
UNIT LENGTH
1480 mm
D
UNIT LENGTH WITH FREE SPACE TO RIGHT SIDE DEVICES ACCESS
2480 mm
E
UNIT HEIGHT
1825 mm
F
UNIT WIDTH
875 mm
G
UNIT WIDTH WITH FREE SPACE TO REAR SIDE DEVICES ACCESS
1875 mm
-
NET WEIGHT
665 Kg
-
NET WEIGHT WITH AUTOMATIC ADHESIVE FEEDER
672 Kg
Содержание MACRO 200
Страница 1: ...ADHESIVE MELTER MACRO 200 INSTRUCTIONS MANUAL MA 5068 ENG 221220 GLUING SOLUTIONS ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 8 14 13 11 15 1 2 3 7 6 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions Macro 200 1480 1120 875 1825 ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5068 ENG MACRO 200 INSTRUCTIONS MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...