background image

Philips Hue Bridge (Hue Hub) is a product owned by Philips. Stitchy is not affiliated with Philips or Signify however Stitchy requires a Zigbee Bridge (Hue Hub, Alexa Echo plus or another Zigbee bridge) for 

Google home and/or Amazon Alexa to operate in conjunction with it. Check with your local wholesaler for further information. Stitchy must be installed by a licensed electrician

Scan the QR code or visit 

stitchy.com.au/industry/

 

ML-ST-R300-NF

ML-ST-D200-NF

Neutral Free

Neutral Free

ML-ST-5CH

ML-ST-1CH

ML-ST-BP-DIM

STITCHY PRODUCT RANGE

BECOME A 

ACCREDITED INSTALLER

HOW DOES

WORK

Содержание ML-ST-BP-DIM

Страница 1: ...ctrician www melec com au stitchy bp ML ST BP DIM Trailing edge phase control Yes Yes Yes AC 220 240V 50Hz 5 150W LED Luminaries IP20 3 0 L 43mm X W 23mm X H 23mm 0 025kg 3 years Google Home Amazon Alexa Zigbee enabled device such as Hue Bridge is required DIMMING METHOD SHORT CIRCUIT PROTECTION OVER CURRENT PROTECTION OVER TEMP PROTECTION RATED VOLTAGE LOAD IP RATING ZIGBEE PROTOCOL SIZE WEIGHT W...

Страница 2: ...e bridge for Google home and or Amazon Alexa to operate in conjunction with it Check with your local wholesaler for further information Stitchy must be installed by a licensed electrician Scan the QR code or visit stitchy com au industry ML ST R300 NF ML ST D200 NF Neutral Free Neutral Free ML ST 5CH ML ST 1CH ML ST BP DIM STITCHY PRODUCT RANGE BECOME A ACCREDITED INSTALLER HOW DOES WORK ...

Страница 3: ...ut our Warranties please go to melec com au legal warranties INSTALLATION WIRING DIAGRAM DISCONNECT MAINS BEFORE PROCEEDING 1 Remove existing wall switch dimmer and disconect the cables 2 Connect first Stitchy BP dimmer s cable to the active cable L 3 Connect second Stitchy BP dimmer s cable to the switched cable going to the LED luminaire 4 Press Stitchy BP dimmer into the switch face plate and r...

Страница 4: ...alling or servicing All components must not be mechanically stressed Be careful not to damage or destroy conductive paths on the circuit board Follow all relevant electrical and safety standards including AS3000 Damage by corrosion will not be honoured as a material defect claim It is the user s responsibility to provide suitable protection against corrosive agents such as moisture condensation an...

Страница 5: ... 3 3 Y YE EA AR RS S I IN NC CL LU UD DE ES S P PA AR RT TS S L LA AB BO OU UR R _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ IIn n c co on njju un nc ct tiio on n w wiit th h y yo ou ur r s st ta an nd da ar rd d p pr ro od du uc ct t w wa ar rr ra an nt ty y Version 10 ...

Отзывы: