Instructions Manual
6-3.Connecting DC Input/Motor Output Connector(J2,J3)
Erroneous connection may cause
breakage of the motor or the driver.
Correctly connect the DC Input/Motor
output connector.
The following items are required:
●Housing for J2 (51067-0200:Molex)
One unit (accessory)
●Housing for J3 (51067-0500:Molex)
One unit (accessory)
●Contact for J2,J3 (50219-9101:Molex)
7 contacts (accessories)
●Manually operated crimping tool
One unit
for AWG24-18(57189-5000:Molex)
(1) Crimp the contact to the cable used for wiring.
(2) Insert the contact into the housing.
Make sure that the housing No. and the connector No. on the main frame are
matched before inserting the contacts.
(3) Connect the housings to the connectors on the main frame.
● The contacts for J2(for DC input) are 2 pieces, and for J3(motor output)
are 5 pieces.
● When inserting, keep pushing J2,J3 housings into the connectors until it is
locked. Also, check if the contacts are not displaced from the housing.
(Surface on which the contacts are inserted)
Housing for J2
Housing for J3
〔DC input Connector〕
〈Crimping〉
〈Connection〉
〈Insertion〉〈Wiring〉
Contact
DC
J2
Power Supply
●Do not power ON/OFF by the relay etc. in the output side of the DC power supply.
2
DC+
DC+24V
0V(GND)
GDB-5F40
DC+24V
0V
1
2
Housing
for J2
DC-
1
A I N
(0.3mm
2
or more)
(0.3mm
2
or more)
-24-
Содержание GDB-5F40
Страница 31: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 31 ...
Страница 37: ...Instructions Manual 10 3 Dimensions Unit mm 37 ...
Страница 40: ...Instructions Manual 40 ...
Страница 41: ...Instructions Manual 41 ...
Страница 42: ...Instructions Manual 42 ...
Страница 43: ...Instructions Manual 43 ...
Страница 44: ...Instructions Manual 44 ...