Instructions Manual
4-3.Setting HOLD CURRENT SELECT switch
A high setting value may cause burn on the
skin due to overheating of the motor.
Do not select a high value beyond the
required.
HOLD CURRENT is set up with the HOLD I. SEL switch.
The ratio of HOLD CURRENT to DRIVE CURRENT can be selected.
The switch is factory-set to [No.3 (approx 40%)].
(1)
●Relationship between the HOLD CURRENT.
HOLD CURRENT
DRIVE CURRENT
Ratio of HOLD CURRENT
(Factory setting)
● HOLD CURRENT changes relative to DRIVE CURRENT setting.
The ratio of HOLD CURRENT set the switch No. to [No.9] : 100% represents
the same as the setting for DRIVE CURRENT.
● When the DRIVE I.SEL switch is set to No.0 ~ No.2, the useful range
of the HOLD I.SEL switch becomes No.1 ~ No.9.
●The greater the ratio of HOLD CURRENT grows, the more heat the motor
generates when is on holding-state.
9
100
8
90
7
80
6
70
5
60
4
50
3
40
0
-
2
30
1
20
Set the HOLD I.SEL switch No. to the ratio of HOLD CURRENT to DRIVE CURRENT
required.
×100
=
Ratio of HOLD CURRENT(%)
DRIVE I.SEL〔No.0~No.2〕
Ratio of
HOLD CURRENT(%)
DRIVE I.SEL〔No.3~No.F〕
HOLD I.SEL No.
Ratio of
HOLD CURRENT(%)
HOLD I.SEL No.
0
10
1
20
2
30
3
40
4
50
5
60
6
70
7
80
8
90
9
100
A I N
-16-
Содержание GDB-5F40
Страница 31: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 31 ...
Страница 37: ...Instructions Manual 10 3 Dimensions Unit mm 37 ...
Страница 40: ...Instructions Manual 40 ...
Страница 41: ...Instructions Manual 41 ...
Страница 42: ...Instructions Manual 42 ...
Страница 43: ...Instructions Manual 43 ...
Страница 44: ...Instructions Manual 44 ...