![background image](http://html1.mh-extra.com/html/melec/adb-2f60b/adb-2f60b_instruction-manual_1767047032.webp)
ADB-2F60B
Instructions Manual
(3) Motor excitation stop input(M.F)
Deterioration of the holding power with
the motor may cause breakage of the machine
or injury.
Check safety before inputting.
① Operating current range : 2.6mA~19.5mA
The photo-coupler turns on with
inter-terminal voltage of 4.5 V~26.4 V.
(Photo-coupler diode V
F
≒ 1.1 V)
● Motor output current is shut off with the photo-coupler ON.
At this time, motor torque changes to detent torque.
● When this signal is input, motor torque may be lost, resulting in failure to
retain the load transported.
In particular, this risk is high with the vertical drive (such as the Z-axis).
② Timing chart
M.F
t1
t2
t1≦300ms
(t1:Time required for the motor to be enabled.)
t2≦5ms
(t2:Time required for the motor output current to be shut off.)
t3≦100ms
(t3:Time required for the motor to be enabled.)
t3
ON
ON
ON
ON
OFF
OFF
Supply
power
Motor
excitation
-32-
Содержание ADB-2F60B
Страница 30: ...ADB 2F60B Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 30 ...
Страница 35: ...ADB 2F60B Instructions Manual 10 3 Dimensions Unit mm 35 ...
Страница 38: ...ADB 2F60B Instructions Manual 38 ...
Страница 39: ...ADB 2F60B Instructions Manual 39 ...
Страница 40: ...ADB 2F60B Instructions Manual 40 ...