background image

Manual

 

M7LL

 

/

 

M70LL

 

Laser

Sensors

  



 

HB

M7LL

M70LL

E.doc

 

page

 

19

 

of

 

23

 

V20130301

   

MEL

 

Mikroelektronik

 

GmbH,

 

Breslauer

 

Str.

 

2,

 

85386

 

Eching

 

/

 

Germany

 

www.MELSensor.com

 

 

M

M

a

a

i

i

n

n

t

t

e

e

n

n

a

a

n

n

c

c

e

e

 

 

 

 

M7LL

‐ 

/

 

M70LL

 

Laser

 

sensors

 

are

 

maintenance

 

free.

 

Because

 

these

 

are

 

optical

 

measurement

 

unit,

 

the

 

optical

 

system

 

has

 

toe

 

be

 

kept

 

free

 

from

 

dirt

 

and

 

dust.

 

This

 

means:

 

the

 

optical

 

system

 

needs

 

to

 

be

 

cleaned

 

from

 

time

 

to

 

time.

 



Tipp:

   

cleaning

 

should

 

be

 

done

 

with

 

a

 

soft

 

towel.

 

  

 

You

 

could

 

use

 

alcohol

 

and

 

/

 

or

 

bezine.

 

 

Avoid

 

finger

 

prints

 

and

 

grease;

 

remove

 

these

 

quickly

 

after

 

mounting!

 

picture

 

:

 

dirty

 

Sensor

 

 

                             

 

   

picture:

 

clean

 

Sensor

 



please

 

note:

 

oily

 

finger

 

prints

 

cause

 

severe

 

measurement

 

errors.

 

The

 

same

 

applies

 

to

 

water

 

drops

 

or

 

other

 

liquids.

 

E

E

n

n

v

v

i

i

r

r

o

o

n

n

m

m

e

e

n

n

t

t

 

 

c

c

o

o

n

n

d

d

i

i

t

t

i

i

o

o

n

n

 

 

S

S

u

u

n

n

l

l

i

i

g

g

h

h

t

t

 

 

 

 

During

 

the

 

installation

 

of

 

sensors

 

take

 

care

 

that

 

no

 

sunlight

 

could

 

radiate

 ‐ 

directly

 

or

 

reflected

 

on

 

a

 

surface

 ‐ 

into

 

the

 

sensors

 

receiving

 

optics.

 

This

 

could

 

cancel

 

the

 

function

 

of

 

the

 

sensor.

 

W

W

a

a

t

t

e

e

r

r

 

 

a

a

n

n

d

d

 

 

o

o

i

i

l

l

 

 

Water

 

drops

 

on

 

the

 

optic

 

system

 

or

 

on

 

the

 

front

 

make

 

severe

 

distortion

 

on

 

the

 

measurement.

 

Water

 

drops

 

work

 

like

 

a

 

lens.

 

They

 

may

 

cause

 

sensors

 

to

 

fail

 

permanently.

 

S

S

p

p

e

e

c

c

i

i

a

a

l

l

 

 

S

S

e

e

n

n

s

s

o

o

r

r

 

 

m

m

o

o

d

d

e

e

l

l

s

s

 

 

Standard

 

sensors

 

were

 

delivered

 

with

 

laser

 

wavelength

 

of

 

650

 

...

 

670

 

nm.

 

For

 

special

 

purpose

 

and

 

on

 

request

 

MEL

 

will

 

deliver

 

other

 

laser

 

wavelength.

 

The

 

technical

 

data

 

for

 

those

 

sensors

 

are

 

basically

 

the

 

same

 

as

 

for

 

650

 

nm

 

sensors.

 

Sensors

 

using

 

different

 

wavelength

 

would

 

not

 

interfere

 

into

 

each

 

other

 

optical

 

system.

 

This

 

allows

 

to

 

use

 

two

 

laser

 

sensors

 

having

 

a

 

laser

 

spot

 

near

 

to

 

the

 

other

 

sensor

 

without

 

interference

 

problems.

 

Sensors

 

with

 

different

 

laser

 

wavelength

 

may

 

hav

 

different

 

laser

 

safety

 

class

 

or

 

different

 

technical

 

data.

  

Содержание M70LL 0.5

Страница 1: ...Sensoren Mess Systeme M7LL M70LL Laser Sensors with integrated Ethernet Interface Manual MEL Mikroelektronik GmbH Breslauer Str 2 D 85386 Eching Tel 49 89 327 150 0 Fax 49 89 319 20 23 www MELsensor de Copyright MEL Mikroelektronik GmbH ...

Страница 2: ...t 7 Noise 7 Measurement accuracy and adjustments 7 Sensor Test Report 7 Linearisation 7 Reaction time and frequency response 7 Adjustable thresholds for the Min and Max Outputs 7 Repeatability 7 Connections 8 Network 8 Ethernet cabling 8 Multi Sensor Arrays 8 Factory Default Setting 8 Sensor heads 8 Special models and options 8 Software 8 Connector specification D Sub 25 9 Electronic unit 10 examp...

Страница 3: ...ures Ethernet interface Network Link Monitoring internal 10 Mbit Option for weak network connections With each TCP packet sensor parameters were sent After a reset the sensor automatically restarts Settings were not reset Factory default parameters could change without notice tot he given documentation Relevant is always the actual interface description of MEL For details contact MEL technical sup...

Страница 4: ... configuration software the settings for exposure time video amplification and laser intensity can be made via Ethernet interface at the PC O Op pt ti ic ca al l d di is st ta an nc ce e m me ea as su ur re em me en nt t s sy ys st te em ms s M M7 7L LL L a an nd d M M7 70 0L LL L Optical measurement systems are used in the touch free metrology The models vary in range spot size and resolution For...

Страница 5: ...educing the dependency from ambient light System set up Montagerichtung RICHTIG Montagerichtung FALSCH M Mo ou un nt ti in ng g o of f t th he e s se en ns so or r h he ea ad d For precise measurement results the sensor must be mounted in a way that the laser beam is perpendicular to the object surface Any inclination will cause a deviation from the real distance The sensor head must be mounted in...

Страница 6: ...te each other S St tr ra ay y l li ig gh ht t S When highly reflective objects are close to the measurement spot mirroring the laser light into the receiver optics then measurement errors may be caused When highly reflective objects are close to the measurement spot mirroring the laser light into the receiver optics then measurement errors may be caused Objects with diffuse reflectivity may not ca...

Страница 7: ...surface reflectivity and creates a output voltage proportional to the distance R Re ea ac ct ti io on n t ti im me e a an nd d f fr re eq qu ue en nc cy y r re es sp po on ns se e Reaction time at analog outputs is extremely fast with laser sensors It is specified to be less than 50 μsec for the M7LL or 5 μsec for the M70LL rise from 0 to 90 of final value With DIP switches in the electronic unit ...

Страница 8: ...hat network activities in the PC would affect the sensor network and vice versa In this case the sensors are in a separate Subnet This helps to keep the sensor network separated from the other networks in your company F Fa ac ct to or ry y D De ef fa au ul lt t S Se et tt ti in ng g IP default address 192 168 122 245 Port 3000 Subnet mask 255 255 255 0 on request before delivery custom IP Addresse...

Страница 9: ...d be also connected to this central ground In this case the shield for the analog output line should be kept separate from other ground connections to avoid ground loops This is the best way to connect potential free inputs o on nn ne ec ct to or r s sp pe ec ci if fi ic ca at ti io on n D D S Su ub b 2 25 5 Pin Signal Color Level Flat cable Remarks 1 Distance output 10 V 2 Error output Yellow 1 3...

Страница 10: ...e es s R RJ J4 45 5 c cr ro os ss se ed d o ov ve er r Pin Signal Connector A Pin Connector B crossed Signal 1 Transmit data Green White 1 Red White Receive data 2 Transmit data Green 2 Red Receive data 3 Receive data Red White 3 Green White Transmit data 4 unused Blue 4 Blau unused 5 unused Blue White 5 Blau Weiß unused 6 Receive data Red 6 Green Transmit data 7 unused Brown White 7 Brown White u...

Страница 11: ... Schaltausgänge mit Anzeige Error 24V 100mA LED red Digital output Ethernet TCP IP factory default IP Address 192 168 122 245 Hysteresis for min max outputs approx 0 5 of range Ambient light 20 000 LUX Life time 50 000h for Laser Diode Isolation voltage 200 V DC 0V to case Max Vibration 10g bis 1kHz Sensor head 20g optional Operating temperature 0 bis 50 C Storage temperature 20 bis 70 C Humidity ...

Страница 12: ... outputs ca 0 5 from range Ambient light 20 000 LUX Life time 50 000 h for Laser Diode Isolation voltage 200 V DC 0V to case Max Vibration 5 g bis 1kHz Sensor head 20g optional Operating temperature min 0 32 F max 40 C 104 F Storage temperature min 30 C 2 F max 75 C 167 F Humidity up to 90 RH non condensing Protection Sensor IP 64 Electronic unit IP 40 Supply 24 V DC 200mA 10 30V Connector at elec...

Страница 13: ...e Receive data packets from sensor Decode data packets see data format Evaluate data information Send command to the sensor C Co om mm mu un ni ic ca at ti io on n c co om mp po on ne en nt ts s TCP Clients and Server are software components in the software development environment These are represented in the compiled application software as ports using protocols commands and data Each sensor has ...

Страница 14: ...and note their respective IP addresses Example Address Sensor 1 192 168 123 222 Address Sensor 2 192 168 123 223 Address Sensor 3 192 168 123 224 Address Sensor 4 192 168 123 225 Address Sensor 5 192 168 123 226 Address Sensor 6 192 168 123 227 Address Sensor 7 192 168 123 224 wrong IP Addresse conflict with sensor Nr 3 Address Sensor 8 192 168 123 229 Address Sensor 9 192 168 124 229 other subnet...

Страница 15: ...ear Year ex 0311 unsigned int Serial Number Cnt 6 2 Production Number 3 digits 001 002 003 999 unsigned int On counter 8 4 hh mm ss unsigned long Reserved 12 20 unsigned char Data Packet Number 32 2 Consecutive numbers natural number 0 1 2 3 999 unsigned int Ethernet transmission rate 34 1 1 10 100 MBit s unsigned char Reserved 1 35 3 unsigned char AMB 38 2 Begin of range unsigned int MB 40 2 Rang...

Страница 16: ...ding the RS 232 prompt could help to find out the actual settings of the sensor Data of the RS 232 Prompt Model Type and Firmware Version of the sensor Serial number Ethernet Stack Status Ethernet Stack transmission rate Ethernet Stack Settings MAC Address working IP Address Subnetz Maske Gateway Address Activity of Web Server Set up value for Max and Min Ethernet Link Status Example fo a RS 232 P...

Страница 17: ...v 0 1 or higher Sensor in normal operation s output and S input not connected Sensor in normal operation s output and S input not connected Remote PC connected to the sensor over Ethernet Remote PC connected to the sensor over Ethernet The PC must be in the same network segment like the sensor The PC must be in the same network segment like the sensor n nt te eg gr ra at te ed d W We eb b S Se er ...

Страница 18: ...xx xxx xxx When the sensor is not powered on you must not receive an answer Whenn you receive an asnwer even when the sensor is not powered then anyone else is using this IP address Check if your routers and switches allow the use of port 3000 Stellen Sie eine direkte make a direct connection You may need a crossed Ethernet cable Use unmanaged switches Network connection to PC failed Check the set...

Страница 19: ... ig gh ht t During the installation of sensors take care that no sunlight could radiate directly or reflected on a surface into the sensors receiving optics This could cancel the function of the sensor W Wa at te er r a an nd d o oi il l Water drops on the optic system or on the front make severe distortion on the measurement Water drops work like a lens They may cause sensors to fail permanently ...

Страница 20: ...nto the beam Never direct the laser onto other people Never direct the laser onto other people Train operators Train operators Before cleaning switch off laser Before cleaning switch off laser Use a piece of paper to locate the invisible beam Use a piece of paper to locate the invisible beam Never use mirrors in the environment Never use mirrors in the environment Shield the workplace a as se er r...

Страница 21: ...ed2 2 unsigned int uiADZMaxValue 2 0xFFFF unsigned int uiADIMaxValue 2 0xFF unsigned int uiADFrequenz 2 30000 unsigned int uiADValuesMax 2 200 unsigned int uiADValues ADVALUESPROTOKOLMAX 2x200 400 unsigned char chADIValues ADVALUESPROTOKOLMAX 1x200 200 unsigned char chADLValues ADVALUESPROTOKOLMAX 1x200 200 _structADValues 860 E Et th he er rn ne et t S Se en ns so or r S So of ft tw wa ar re e I ...

Страница 22: ...nect Befehl SOCKADDR_IN serv_addr MUST have value AF_INET serv_addr sin_family AF_INET hand over port number of sensor serv_addr sin_port htons atoi 3000 hand over IP address of sensor serv_addr sin_addr S_un S_addr inet_addr 192 168 123 224 while bRunSocket bRunConnect TRUE Socket holen für TCP SOCK_STREAM sTCP socket AF_INET SOCK_STREAM 0 Socket error if sTCP INVALID_SOCKET sTCP 0 bRunConnect FA...

Страница 23: ...ase socket closesocket sTCP WSACleanup Use the send function for sending data to the sensor Like with the recv function it is necessary to set up connection to the sensor before using the send fucntion In the above example you could replace recv function with send function Data Buffer data buffer contains the command to set the sensor in single mode char chBuffer 2 0x14 0x01 send sTCP chBuffer 2 N...

Отзывы: