Setting the working IP address is available only when the Scanner is set to Default-IP-Address
→
connect the Reset-IP-Pin to ground !
This string must be sent:
Nr.
hex
Register / function
Meaning
1
0x22
Register call 0x22
Command to register 0x22 : save new
network settings
2 0x55
3 0xAA
4 0x55
5 0xAA
6 0x55
7 0x00
8 0x00
9 0x00
10 0x00
11 0x00
12 0x00
13 0x00
14 0x00
15 0x00
Password
The password (or passphrase) is
checked.
This is to avoid that the re-writing of
the IP address is not made by error.
16
192
Gateway 1
st
octet
17
168
Gateway 2
nd
octet
18
123
Gateway 3
rd
octet
19
1
Gateway 4
th
octet
20 255
Subnet
mask
1
st
octet
21 255
Subnet
mask
2
nd
octet
22 255
Subnet
mask
3
rd
octet
23 0
Subnet
mask
4
th
octet
24
192
IP address 1
st
octet
25
168
IP address 2
nd
octet
26
123
IP address 3
rd
octet
27
224
IP address 4
th
octet *
28 [PORT:LOWORD]
0xB8
29 [PORT:HIWORD]
0x0B
port address = 3000
30 0x00
31 0x00
ending
* the IP address depends on the set value.
After flashing the EEPROM, the Blue Box electronic system must be reset (power down and up again).
When the Reset-IP-Pin is released from ground, new working IP address will be set valid.
Please note:
Set the working IP address with the MEL demo and configuration software Rev. 2.4.0.2 or higher.
Use Tab 11 for set up of the working-IP address, alternatively use the Web-Browser (with firmware 1.10.6 or
higher).
R
R
e
e
p
p
r
r
e
e
s
s
e
e
n
n
t
t
a
a
t
t
i
i
o
o
n
n
o
o
f
f
t
t
h
h
e
e
S
S
e
e
r
r
i
i
a
a
l
l
-
-
N
N
u
u
m
m
b
b
e
e
r
r
The serial number is encoded in the last 3 Bytes of Mac-Address.
Nibble ** - Nr.
Information
Range
Remarks
1
encoding
0 … F
F hex = 16 decimal
2
Month
0 … C
C hex = 12 decimal
3
Year 10s
0 … F
4
Year 1s
0 … F
5
Serial-Number
0 … F
6
Serial-Number
0 … F
Max. = 255
** a Nibble is a half Byte = 4 Bit