After getting the desired area of the second time computation, press 

+/=

 to enter the addition 

mode. A “+” icon would appear on LCD.       

                                                                                                                                 

 

z

 

Press RM key to recall the first calculated area for the addition. The “M+” icon will 
disappear and the stored memory will be automatically cleared; 

 

 

z

 

Press +/= key, the sum of both areas is shown on the lower portion of the screen;   

 

z

 

Repeat the steps above to keep adding the measured area. 

Volume 

z

 

Press 

SET

 key to enter volume mode, and the 

 will appear on the display  for 

calculation of a room volume;   

 

z

 

The length character “L” on the screen will blink showing length measurement will be taking. 
Press READ key to take length measurement, the result will be displayed on upper portion of 
screen. (Step 1)      

                                                                                                               

 

z

 

The width character “W” on the screen will blink showing the next measurement to take. 
Press 

READ

 key to take width measurement, the result will be displayed on upper portion of 

screen. (Step 2);     

                                                                                                               

 

z

 

The height character “H” on the screen will blink showing the next measurement to take. 
Press 

READ

 key to take height measurement, the result will be displayed on upper portion of 

screen. (Step 3);                                                                       

z

 

Then the volume is automatically displayed on the lower portion of the screen; 

 

 

 

6

Содержание KC-100B-1

Страница 1: ...Manifold Electronic Gauge Model KC 100B 1 Operation Manual...

Страница 2: ...ernational safety rule SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any l...

Страница 3: ...of upper line is the current measuring result and the data of lower line is the memory computing result D M Memory input key Input the length area or volume into memory E READ On read key Press this k...

Страница 4: ...surface z Keep pressing the READ key and move the tool to get the dynamical readings and the measured distance will be displayed on upper portion of the screen z Press the SET key and the READ key to...

Страница 5: ...n of the screen z Repeat the steps above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the display z Press the READ key...

Страница 6: ...will toggle back and forth between the length and width measurement on the upper portion of the screen Press SET key to clear the data on the portion of the screen then can begin the new calculation o...

Страница 7: ...calculation of a room volume z The length character L on the screen will blink showing length measurement will be taking Press READ key to take length measurement the result will be displayed on upper...

Страница 8: ...ar on LCD z Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section z After getting the calculated volu...

Страница 9: ...z When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accura...

Страница 10: ...emperature 0 to 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 142mm 70mm 40mm Weight About 110g WARRANTY The product is warranted to be free from defects in materials and w...

Отзывы: