9

TECHNICAL SPECIFICATIONS

 

Name Manifold 

electronic 

gauge 

Type  

KC-100B-1 

Recommended use 

Indoor 

Measurement range 

2’ to 53’ (0.6 to 16m) 

Length 9999’ 

11’’ 

(9999.99m) 

Area 

99999.9 sq ft (99999.9

Calculation range 

Volume 

999999 cu ft (999999m

3

Resolution 0.01m 
Wavelength of laser 

630~660nm 

Temperature range 

0

 to +40

 

Laser Class 

Class II 

Power supply 

One 9V battery 

Power consumption 

<50mA 

Automatic off 

The tool will be automatically off after 30 
seconds disabling. 

Operating temperature 

0℃ to 40℃

 

Operating humidity 

30%

70% 

Storage environment 

-20

℃~

+60

℃,≤

85%

w/o battery

 

Size 142mm

×

70mm

×

40mm 

Weight About 

110g 

 

WARRANTY

 

The product is warranted to be free from defects in materials and workmanship provided with 

related certificate for a period of one year from the date of purchase. 

Notice: 

The warranty does not apply to the following conditions 

z

 

Disassembling the laser tool will void the warranty. 

z

 

Any damage resulting from, but not limited to wear, water, being dropped or repairs 
attempted by others. 

   
Tips:Most parts of the product could be recycled, please refer to your local regulations for 
disposing of them instead of throwing into the dustbin.   

Содержание KC-100B-1

Страница 1: ...Manifold Electronic Gauge Model KC 100B 1 Operation Manual...

Страница 2: ...ernational safety rule SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any l...

Страница 3: ...of upper line is the current measuring result and the data of lower line is the memory computing result D M Memory input key Input the length area or volume into memory E READ On read key Press this k...

Страница 4: ...surface z Keep pressing the READ key and move the tool to get the dynamical readings and the measured distance will be displayed on upper portion of the screen z Press the SET key and the READ key to...

Страница 5: ...n of the screen z Repeat the steps above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the display z Press the READ key...

Страница 6: ...will toggle back and forth between the length and width measurement on the upper portion of the screen Press SET key to clear the data on the portion of the screen then can begin the new calculation o...

Страница 7: ...calculation of a room volume z The length character L on the screen will blink showing length measurement will be taking Press READ key to take length measurement the result will be displayed on upper...

Страница 8: ...ar on LCD z Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section z After getting the calculated volu...

Страница 9: ...z When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accura...

Страница 10: ...emperature 0 to 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 142mm 70mm 40mm Weight About 110g WARRANTY The product is warranted to be free from defects in materials and w...

Отзывы: