Deleting an ID number in code matching mode:
In standby mode, press and hold down the
CODE
key of the LCD display for 3 seconds. When you hear "Bi" once,
release the key. Then the system will enter code matching mode. Press the
+
or
-
key to select the location of the tire
to be deleted, and press and hold down the
SET
key for 3 seconds. If you hear "Bi" twice, it means that the tire's ID
number is deleted. In this way, perform one of the following steps to exit the settings state or enter normal working
status: (1) do not press any key for 3 consecutive minutes to exit the settings state; (2) press and hold down the
CODE
key for 3 seconds. After you hear "Bi" once, release the key. The LCD display will return to normal working status.
Deleting all the ID numbers:
In standby mode, short press the
CODE
key of the LCD display. When you hear "Bi" once, the system will enter ID
number querying mode. Then press and hold down the
LINK
key for 3 seconds. When you hear "Bi" once, release the
key. Then "DEL ALL" will be showed on the LCD display, indicating that all tires' ID numbers will be deleted. Short
press the
SET
key to confirm and delete all the ID numbers. Then the LCD display will make a long "Bi" sound for 3
seconds and will return to normal working status. If you short press the
CODE
key instead of the
SET
key, all the ID
numbers will not be deleted and the LCD display will return to ID number querying mode. If you do not press any key
for 3 consecutive minutes, the LCD display will return to normal working status.
8.2.4
Restoring Factory Settings
When the LCD display is turned off, press the
SET
key to turn on it. When you hear "Bi" once, release the key. Then
default alert parameters will be restored, and original ID numbers of tires will remain unchanged.
After factory settings are restored, related parameters are as follows:
Pressure unit
PSI
High pressure alert threshold
175 PSI (12.1 BAR)
Low pressure alert threshold
100 PSI (6.9 BAR)
Temperature unit
°C
High temperature alert threshold
70°C (158 °F)
8.2.5
Setting Alert Thresholds
After the LCD display is turned on, long press the
SET
key. When you hear "Bi" once, release the key. Then you can
set high temperature, low temperature, high pressure, and low pressure alert thresholds of vehicle's containers.
Pressure unit:
Press the + or - key to select a pressure unit.
Temperature unit: