PYROCON19
Owner’s manual & Technician Settings
Pg. 14
Technician settings (Cont’)
P09 – PYROSENSE sensors connected to system
Press the [SELECT] and [+] buttons simultaneously.
“P09” and the MAC address of the first sensor will appear on display.
Use the [+] and [-] buttons to select sensor. When selected, Press the
[ON] button to enable (ON) or disable (OFF) the sensor.
Repeat the operation for other sensors (1-8) – default: 1-ON, 2-8 OFF.
Sensors MAC Address:
- MAC 1 - PYROSENSE #1
(1
st
aerial sensor)
- MAC 2 - PYROSENSE #2
(2
nd
aerial sensor)
- MAC 3 - PYROSENSE #3
(3
rd
aerial sensor)
- MAC 4 - PYROSENSE #4
(4
th
aerial sensor)
- MAC 5 - PYRO-GROUND #1 (1
st
ground sensor)
- MAC 6 - PYRO-GROUND #2 (2
nd
ground sensor)
- MAC 7 - PYRO-GUTTER #1 (1
st
gutter sensor)
- MAC 8 - PYRO-GUTTER #2 (2
nd
gutter sensor)
After enabling required sensors, an error message “SensErr” and the
number of the first missing sensor will appear on display indicating that
this sensor is not connected to the system.
Connect the first sensor to the system and wait for the error message to
disappear or change to the next missing sensor.
Connect the second sensor to the system and repeat the operation.
Repeat the operation for all sensors in the system.
Sensor
enabled
Sensor
disabled
Connecting sensors to the system
Enable or disable
sensors using
technician parameter
P09.
The system will start
looking for the
sensors.
An error messege
“SnsErr” and the
number of the first
missing sensor will
appear on display.
Connect the first
sensor to the system
and wait until it is
recognized,
The error will
disappear or change
to indicate the next
missing sensor.
Connect the other
sensors to the
system one by one
until the error
disappears.
Cont’
Communication
error with snow
sensors