Checking Power Status
The status of the power supplies can be viewed in the web interface under "System
→
Redundant Power Supply"
(depending on the equipment, i. e. if one or two power supplies are installed, the web interface displays this
status).
Connector Type:
5-pol. DFK
Pin Assignment:
1: N/-
2: not connected
3: PE (Protective Earth)
4: not connected
5: L/+
Input Parameter
——————————————————————————
Nominal Voltage Range:
U
N
=
100-240 V
∼
100-200 V
Maximum Voltage Range:
U
N
=
90-254 V
∼
90-240 V
Nominal Current:
I
N
=
1.0 A
∼
0.6 A
Nominal Frequency Range:
f
N
=
50-60Hz
Maximum Frequency Range:
f
max
=
47-63Hz
Output Parameter
——————————————————————————
Maximum Power:
P
max
=
50 W
Max. Heat Emission:
E
therm
=
180.00 kJ/h (170.61 BTU/h)
N/-
L/+
AD10
PWR
Power
U
100 V - 240 V
N
=
U
V - 254 V
max
= 90
I
= 1.0A
N
f
= 50 - 60Hz
N
U
100 V - 200 V
N
=
U
V - 240 V
max
= 90
I
= 0.6A
N
2
3
4
5
1
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Only qualified personnel (electricians) may connect the device.
- Never work with open terminals and plugs while the power is on.
- All connectors must be protected against touching live parts with
a suitable plug housing!
- Note: Always ensure safe wiring!
- Important: The device must be connected to a proper grounding (PE).
18
Date: 2nd September 2019
LANTIME M300/GNS/RPS