5.3 DCLS Time Code (Unmodulated) Input
Input Signal:
DCLS Time Code, Pulse-Width
Modulated (e.g., IRIG-B00x)
Insulation Voltage:
3750 V
rms
Typ. Input voltage:
5 V DC
Internal Resistor:
220
Ω
Max. Input Current:
60 mA
Connector Type:
BNC Female, Insulated
Cable:
Coaxial Cable, Shielded
TC DCLS In
5.4 AM Time Code (Modulated) Input
Input Signal:
Unbalanced Sine Wave Signal
Signal Level:
600 mV
pp
/ 8 V
pp
(MARK/SPACE)
600
Ω
Termination
Insulation Voltage:
3000 V DC
Connector Type:
BNC Female, Insulated
Cable:
Coaxial Cable, Shielded
TC AM In