4.1 HPS100 - Global Configuration

Operating Mode

If supported, there is an option to run a NTP service in Server mode with hardware timestamp support. Select
between PTP and NTP mode at this step. It is not possible to run both modes at the same time on one TSU card.

Select Profile

User can choose among preselected sets of PTP parameters defined in profiles usually used in different indus-
tries. If the default setting “Custom“ is selected, the user can select any parameter combination available in the
global configuration section as long as the PTP standard allows it. Depending on the selected profile, there
might be profile specific parameters available which can be found in the “Profile Specific Parameters“ section
below the standard PTP parameters sections.

8

Date: 14th November 2019

IMS-HPS-100 Setup Guide

Содержание IMS-HPS-100

Страница 1: ...MANUAL IMS HPS 100 Setup Guide Hot Plug Module 14th November 2019 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...nts 3 2 2 Supply Voltage 3 2 3 Cabling 4 3 Replacement or Installation of a Hot pluggable IMS Module 5 4 HPS 100 PTP SyncE Hardware NTP Interface 6 4 1 HPS100 Global Configuration 8 4 2 Option Output...

Страница 4: ...kuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2016 05 03 IMS HPS 100 Setup...

Страница 5: ...to the manufacturer for maintenance Exchange of hot swap components Ensure that components which will be replaced during operation always be treated with the utmost care Avoid contact with live compon...

Страница 6: ...of high voltage devices 2 2 Supply Voltage WARNING This device is powered by a dangerous voltage Nonobservance of the safety instructions of this manual may lead to serious damage to persons and prop...

Страница 7: ...work done the connectors particularly when connectors are opened may never be carried out when the installation is energized All connectors must be covered to prevent from accidental contact to life p...

Страница 8: ...ilt in module Pull the module carefully out of the holding rail Note that the module is firmly anchored in the connector block of the housing You need a certain amount of force to release the module f...

Страница 9: ...Delay Mechanism Up to 128 messages second per client NTP Mode NTP Server mode 8 ns time stamp accuracy NTPD Software Service 15 000 req s 1588 Clock Mode 1 Step 2 Step for both Master and Slave opera...

Страница 10: ...off Master Mode off green Slave Mode yellow off Passiv Mode off yellow uncalibrated red red stopped Performance Level Options Option Unicast Delay NTP PTPv1 PTP Clients Req s Req s Monitoring PL A 8...

Страница 11: ...elected sets of PTP parameters defined in profiles usually used in different indus tries If the default setting Custom is selected the user can select any parameter combination available in the global...

Страница 12: ...he current LANTIME firmware manual 4 2 Option Output Configuration The HPS100 module is equipped with one Gigabit Ethernet SFP RJ45 Combo Port for network synchronization and two SMA ouput connectors...

Страница 13: ...100 firmware version from our website https www meinbergglobal com english sw refclock updates htm The update file can be uploaded to the HPS100 by first choosing the file on your local computer with...

Страница 14: ......

Отзывы: