6.2 Pulse outputs
Page 9
6.2 Pulse outputs
The satellite controlled clock GPS164 is equipped with a pulse generator providing three output channels inde-
pendently congurable using the software GPSMON32. The active state of each output is settable to either high
or low, pulse duration may be congured between 10ms an 10s in steps of 10ms. By default, pulse outputs are
disabled until rst synchronization of the receiver, however outputs can be congured to be enabled immediately
after power up. Pulses are output via three bre optic transmitters (850 nm, ST-Connector).
The following modes can be congured for each channel independently:
Timer mode:
Three on- and o-times per day per channel programmable
Cyclic mode:
Generation of peropdically repeated pulses.
A cycle time of two seconds would generate a pulse at
0:00:00, 0:00:02, 0:00:04 etc.
DCF77-Simulation
mode:
The corresponding output simulates the DCF77 time telegram.
The time marks are representing the local time as congured by the user.
Time zone of the signal is congurable to either local time or UTC.
DCF77-M59
Generates a modied DCF77 telegram with a 500 ms pulse inserted in
the 59th second gap. Time zone of the signal is congurable to either local time or UTC.
Single Shot Mode:
A single pulse of programmable length is generated once a day at a
programmable point of time
Per Sec.
Per Min.
Per Hr. modes:
Pulses each second, minute or hour
Status:
One of three status messages can be emitted:
'position OK':
The output is switched on if the receiver was able to
compute its position
'time sync':
The output is switched on if the internal timing is
synchronous to the GPS-system
'all sync':
Logical AND of the above status messages.
The output is active if position is calculated AND the
timing is synchronized
Time code
The un-modulated IRIG or AFNOR signal of the built in time code generator
is made available at the respective output.
COM Time String
The time string of the serial port COM1 is made available at the respective
output.
Idle-mode:
The output is inactive.
GPS164
Date: 27th January 2016
9
Содержание GPS164-LQ/PPFO-3/REL-1/DAHS
Страница 1: ...MANUAL GPS164 PPFO 3 REL 1 DAHS 27th January 2016 Meinberg Radio Clocks GmbH Co KG ...
Страница 2: ......
Страница 6: ...Page 2 1 General Details 2 Date 27th January 2016 GPS164 ...
Страница 16: ...Page 12 6 GPS164 Features 6 4 4 IRIG Standard Format 12 Date 27th January 2016 GPS164 ...
Страница 17: ...6 4 Time code outputs Page 13 6 4 5 AFNOR Standard Format GPS164 Date 27th January 2016 13 ...