General Information about DCF77

The radio remote clocks made by Meinberg receive the signal from the long wave
transmitter DCF77. This long wave transmitter installed in Mainflingen near Frank-
furt/Germany transmits the reference time of the Federal Republic of Germany. This
time reference is either the Central European Time (Mitteleuropäische Zeit, MEZ) or
the Central European Summer Time (Mitteleuropäische Sommerzeit, MESZ). The
transmitter is controlled by the atomic clock plant at the Federal Physical Technical
Institute (PTB) in Braunschweig/Germany and transmits the current time of day, date
of month and day of week in coded second pulses. Once every minute the complete
time information is available.

At the beginning of every second the amplitude of the high precision 77.5 kHz

carrier frequency is lowered by 75% for a period of 0.1 or 0.2 sec. The length of these
time marks represent a binary coding scheme using the short time mark for logical
zeroes and the long time mark for logical ones. The information on the current date
and time as well as some parity and status bits can be decoded from the time marks of
the 15th up to the 58th second every minute. The absence of any time mark at the 59th
second of a minute signals that a new minute will begin with the next time mark.

Our radio remote clocks decode the highly accurate information on date and time

within a wide range around Germany. So some of our clocks are installed in Bilbao/
Spain as well as in the city of Umeå in northern Sweden - fully satisfying the
requirements of the users. The radio remote clocks automatically switch to summerti-
me and back. The reception of the time information is free of charge and does not need
to be registered.

Generally it is important to position the antenna in an optimal way. It should be

mounted at least 30 centimeters away from the clock unit and from solid steel. The
antenna should be aligned at a right angle to the direction of the transmitter (Frank-
furt).

Figure: Decoding Scheme

M

Start of Minute (0.1 sec)

R

RF Transmission via secondary antenna

A1

Announcement of a change in daylight saving

Z1, Z2

Time zone identification

Z1,Z2 = 0,1:

Daylight saving disabled (MEZ)

Z1,Z2 = 1,0:

Daylight saving enabled (MESZ)

A2

Announcement of a leap second

S

Start of time code information (0.2 sec)

P1, P2, P3

Even parity bits

Содержание DCF77C51

Страница 1: ...DCF77C51 Technical Information Operating Instructions FUNKUHREN...

Страница 2: ...Werner Meinberg Auf der Landwehr 22 D 31812 Bad Pyrmont Telefon 49 52 81 9309 0 Telefax 49 52 81 9309 30 Internet http www meinberg de E Mail info meinberg de May 28 2002...

Страница 3: ...Port 9 Serial Input and Output Drivers 9 Transmission Speed 9 Framing 10 Output mode 10 Time Zone 10 Pulse Outputs 10 DIL Switches 11 Technical Specifications 12 CE Label 13 Format of the Meinberg St...

Страница 4: ......

Страница 5: ...some parity and status bits can be decoded from the time marks of the 15th up to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute wil...

Страница 6: ...6...

Страница 7: ...current time message an additional plausibility check against the previous time message is performed If that plausibility check passes too the real time clock on the board is adjusted corresponding t...

Страница 8: ...lled at least 30 cm away from the clock and from steel girders or plates If the antenna is installed properly and the signal from DCF77 can be received without strong distortions the green LED labeled...

Страница 9: ...ivers need to be connected only if a serial string shall be sent on request Lever 10 of the DIL switch lets the user select either RS 232 input or current loop input It is not possible to use both the...

Страница 10: ...new minute begins Levers 6 and 7 are used to select the desired mode of operation SW 6 SW 7 String Mode on on once persecond off on once perminute on off onrequestonly off off reserved Time Zone Lever...

Страница 11: ...0 9600 19200 SW4 SW5 Framing 7E1 7E2 8N1 8N2 SW6 SW7 Output Mode per second per minute on request SW8 Timezone UTC MESZ MEZ SW9 reserved SW10 Serial Input 20mA RS232 default settings framing 7E2 baudr...

Страница 12: ...rned off the on board RTC keeps the time based on XTAL for more than 48 hours gold cap rsp more than 10 years lithium battery RELIABILITY OF OPERATION Microprocessor supervisory circuit provides watch...

Страница 13: ...coaxial RF connector BNC type POWER SUPPLY 230V AC 50Hz 15V only when using 20mA current loop PHYSICAL DIMENSIONS Rolec Technobox TBA 084 L x B x H 160mm x 81mm x 62mm AMBIENT TEMPERATURE 0 50 C HUMI...

Страница 14: ...e day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second uv clock status characters u clock has not synchronized after reset sp...

Страница 15: ...ord DSUB 25 Connector Pin Assignments 1 14 P_SEC out collector 2 RxD in 15 P_SEC out emitter 3 TxD out 16 P_MIN out collector 4 RTS connected with CTS 17 P_MIN out emitter 5 CTS connected with RTS 18...

Страница 16: ...16...

Страница 17: ...17 Component Layout...

Страница 18: ...shall be wired to operate as active output a connection from the pin labeled pass_out to Vcc 5V must be provided The pin labeled act_out is pulled down to the auxiliary 15V supply which must be made...

Страница 19: ...he pin labeled pass_in to Vcc 5V must be provided The pin labeled act_in is pulled down to the auxiliary 15V supply which must be made available by the user active current loop input with auxiliary 15...

Страница 20: ......

Отзывы: