background image

15

Connectors

Name

Type

Signal

Cable

Serial Interface

25 pin SUB-D

RS232

shielded data line

20mA

Pulse Outputs

pulse per second
pulse per minute

Antenna

BNC

77.5kHz

shielded coaxial line
(RG174/RG58)

Power Supply

230V /AC

power supply cord

DSUB-25 Connector Pin Assignments

1

14

P_SEC out, collector

2

RxD in

15

P_SEC out, emitter

3

TxD out

16

P_MIN out, collector

4

RTS (connected with CTS)

17

P_MIN out, emitter

5

CTS (connected with RTS)

18

6

DSR (connected with DTR)

19

7

GND

20

DTR (connected with DSR)

8

P_SEC (RS232)

21

-act_in

9

-pass_in / +act_in

22

10

+pass_in

23

11

cur5V out

24

curr_loop -15V in

12

+pass_out

25

-act_out

13

-pass_out / +act_out

DB25 connector, female, front view

Содержание DCF77C51

Страница 1: ...DCF77C51 Technical Information Operating Instructions FUNKUHREN...

Страница 2: ...Werner Meinberg Auf der Landwehr 22 D 31812 Bad Pyrmont Telefon 49 52 81 9309 0 Telefax 49 52 81 9309 30 Internet http www meinberg de E Mail info meinberg de May 28 2002...

Страница 3: ...Port 9 Serial Input and Output Drivers 9 Transmission Speed 9 Framing 10 Output mode 10 Time Zone 10 Pulse Outputs 10 DIL Switches 11 Technical Specifications 12 CE Label 13 Format of the Meinberg St...

Страница 4: ......

Страница 5: ...some parity and status bits can be decoded from the time marks of the 15th up to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute wil...

Страница 6: ...6...

Страница 7: ...current time message an additional plausibility check against the previous time message is performed If that plausibility check passes too the real time clock on the board is adjusted corresponding t...

Страница 8: ...lled at least 30 cm away from the clock and from steel girders or plates If the antenna is installed properly and the signal from DCF77 can be received without strong distortions the green LED labeled...

Страница 9: ...ivers need to be connected only if a serial string shall be sent on request Lever 10 of the DIL switch lets the user select either RS 232 input or current loop input It is not possible to use both the...

Страница 10: ...new minute begins Levers 6 and 7 are used to select the desired mode of operation SW 6 SW 7 String Mode on on once persecond off on once perminute on off onrequestonly off off reserved Time Zone Lever...

Страница 11: ...0 9600 19200 SW4 SW5 Framing 7E1 7E2 8N1 8N2 SW6 SW7 Output Mode per second per minute on request SW8 Timezone UTC MESZ MEZ SW9 reserved SW10 Serial Input 20mA RS232 default settings framing 7E2 baudr...

Страница 12: ...rned off the on board RTC keeps the time based on XTAL for more than 48 hours gold cap rsp more than 10 years lithium battery RELIABILITY OF OPERATION Microprocessor supervisory circuit provides watch...

Страница 13: ...coaxial RF connector BNC type POWER SUPPLY 230V AC 50Hz 15V only when using 20mA current loop PHYSICAL DIMENSIONS Rolec Technobox TBA 084 L x B x H 160mm x 81mm x 62mm AMBIENT TEMPERATURE 0 50 C HUMI...

Страница 14: ...e day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second uv clock status characters u clock has not synchronized after reset sp...

Страница 15: ...ord DSUB 25 Connector Pin Assignments 1 14 P_SEC out collector 2 RxD in 15 P_SEC out emitter 3 TxD out 16 P_MIN out collector 4 RTS connected with CTS 17 P_MIN out emitter 5 CTS connected with RTS 18...

Страница 16: ...16...

Страница 17: ...17 Component Layout...

Страница 18: ...shall be wired to operate as active output a connection from the pin labeled pass_out to Vcc 5V must be provided The pin labeled act_out is pulled down to the auxiliary 15V supply which must be made...

Страница 19: ...he pin labeled pass_in to Vcc 5V must be provided The pin labeled act_in is pulled down to the auxiliary 15V supply which must be made available by the user active current loop input with auxiliary 15...

Страница 20: ......