2 Overview DCF600HS
Timer Mode
This mode simulates a programmable day assigned timer. Three turn-off and turn-on times are programmable for
each output. If you want to program a switchtime, change the turn-on time "On" and the corresponding turn-off
time "Off". A turn-on time later than the turn-off time would cause a switch program running over midnight. For
example a program "On"10.45.00, "Off" 9.30.00 would cause an active ouput from 10.45 to 9.30 (the next day!). If
one or more of the three switching times are unused just enter the same time into the values "On" and "Off". In
this case the switch time does not affect the output.
As already mentioned, the outputs home position is selected by "active: high or low".
Time Slots
In this mode, you can select defined time slots. "Number of Time Slots" determines the number and length of
the time slots based to one minute. The "Pre-limit buffer" allows to set a premature shutdown. This can be
configured in the range between 50ms and 500ms to prevent overlap of time slots.
Example:
•
Number of Time Slots = 10
•
Pre-limit buffer = 500ms
Time slots 1 and 2 are enabled (0 - 6s and 6 - 12s).
In fact, the outputs triggers from 0 - 11,5s.
DCF600HS
Date: 24th July 2018
7