background image

MANUAL

DCF600HS

DCF Clock with serial Interface

24th July 2018

Meinberg Funkuhren GmbH & Co. KG

Содержание DCF600HS

Страница 1: ...MANUAL DCF600HS DCF Clock with serial Interface 24th July 2018 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...s 4 2 7 Pulse Outputs 4 3 Configuration DCF600HS 8 3 1 Configuration mit MBGMON 8 3 1 1 Firmware Updates 11 3 2 Configuration with Meinberg Device Manager 12 4 Time Strings 14 4 1 Format of the Meinbe...

Страница 4: ...15th up to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute will begin with the next time mark Our radio remote clocks decode the high...

Страница 5: ...1 5 KV DC 2 3 Housing Technical Specifications The receiver module is mounted in a plastic housing for 35mm DIN mounting rails Two status LEDs for modulation and free running mode the BNC antenna con...

Страница 6: ...perly and the signal from DCF77 can be received without strong distortions the Mod LED starts blinking exactly once per second corresponding to the time marks from DCF77 If this LED flashes intermedia...

Страница 7: ...of photocoupler 2 PP 2 Screw clamp 4 Collector of photocoupler 2 PP 2 Screw clamp 5 ground earth The DCF600HS generates a PPS pulse per second PP 1 and a PPM pulse per minute PP 2 This pulses have a...

Страница 8: ...Collector pulse duration 200 ms Photocoupler Outputs IC1 TLP181 IC9 TLP181 PP 2 PP 1 4 3 2 1 A K E C A K E C Connection IC1 TLP181 IC9 TLP181 PP 2 PP 1 4 3 2 1 A K E C A K E C DCF600HS VDD max 70V GN...

Страница 9: ...time between 0 and 24 hours however usually a cycle times that cause a constant distance between all consecutive pulses make sense DCF77 Marks In DCF77 Marks mode the selected output simulates the te...

Страница 10: ...itching times are unused just enter the same time into the values On and Off In this case the switch time does not affect the output As already mentioned the outputs home position is selected by activ...

Страница 11: ...ting systems the Meinberg Device Monitor is available a comprehensive program that can be used to perform not only configuration and monitoring but also firmware updates 3 1 Configuration mit MBGMON T...

Страница 12: ...d rates and ports The tab COM1 is considered in connection with an version of the DCF600HS RS485 It should be noted that for a RS485 COM 0 is inactive Impulse The program MBGMON has the ability to con...

Страница 13: ...Information By selecting the tab Revision different Informations Serial number Firmware can be shown 10 Date 24th July 2018 DCF600HS...

Страница 14: ...er to load the appropriate software during operation of DCF600HS you must have the Flash program mbgflash exe included to start First select Processor the designated processor SAM3U Then check under C...

Страница 15: ...ollowing Linux distributions Ubuntu Mint Linux Debian SUSE Linux CentOS Documentation https www meinbergglobal com download docs sw english mbgdevman pdf Download https www meinbergglobal com english...

Страница 16: ...all settings back to their default values For more information please refer to the Meinberg Device Manager manual Firmware Update With mbgdevman you can conveniently proceed a firmware update After r...

Страница 17: ...uv clock status characters depending on clock type u GPS clock is running free without exact synchr PZF time frame not synchronized DCF77 clock has not synchronized after reset space 20h GPS clock is...

Страница 18: ...yy year of the century 00 99 w the day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second xxxx time zone indicator UTC Univers...

Страница 19: ...f local timezone related to UTC in hours and minutes ac clock status characters a clock has not synchronized after reset space 20h clock has synchronized after reset c GPS receiver has not checked its...

Страница 20: ...leading signs are replaced by a space character 20h e longitude the following characters are possible E east of Greenwich W west of Greenwich hhhh altitude above WGS84 ellipsoid in meters leading sign...

Страница 21: ...minutes 00 59 ss seconds 00 59 or 60 while leap second ss fractions of seconds 1 10 1 100 A Status A time data valid V time data not valid bbbb bb latitude of receiver position in degrees leading sig...

Страница 22: ...or of message ASCII 0 code 30h TSQ Telegram number ASCII 0 code 30h CC Command code ASCII S for SET code 53h CS Command code ASCII A for ALL code 41h ST Time status ASCII C for valid time code 43h yym...

Страница 23: ...uipment EN55024 2010 Limits and methods of measurement of Immunity characteristics of information technology equipment EN 50581 2012 Technical documentation for the assessment of electrical and electr...