Manual ME-582x Series
Revision 0.9
5 Appendix
page 30
Meilhaus Electronic
Timer resolution
programmable
15.15 ns (1 Tick)
Input level
see the following tables
Isolation voltage
U
ISO
(f = 60
Hz, t = 60 s)
max. 1000
VAC
rms
Reference ground
isolated from PC ground
GND_EXT
Opto-Isolated Inputs
Static values
Conditions: TA=25 °C
Measured Quantity
Test Criterion
MIN
Type
MAX
Unit
U
in,H
5
60
V
U
in,L
0
2.2
V
R
in
U
in
=24 V
4.3
kΩ
I
in
U
in
=24 V
5.5
6
mA
Limiting Values
Measured
Quantity /Criterion
Condition/Explanation
Value
URWM over-voltage pro-
tection for inputs
max. 600 W pulse power at a pulse width
of 1 ms
64.4 V
Opto-Isolated Outputs
Conditions: T
A
=25 °C
Output-drivers
sink
2 x ULN2803 (ME-5820)
+ 2 x ULN2803 (ME-5821)
source
2 x ISO1H811G (ME-5820)
+ 2 x ISO1H811G (ME-5821)
External supply
U
ext
15…30 V
U
Lmax
U
ext
For further specifications see chapter sink driver resp. source driver
Sink Driver (UDN2803)
Measured
Quantity
Test Criterion
MIN
Type MAX
Unit
I
OUT
=I
C
(output cur-
rent)
per channel
50
mA
See also characteristics curves in picture 18