Manual ME-582x Series
Revision 0.9
3 Hardware
page 14
Meilhaus Electronic
Picture 6: Collector current against saturation voltage
Picture 7: Collector current against duty cycle and number of
active channels in use
To supply the sink output drivers, an external power supply has to be con-
nected to VCC_EXT (Pin 10, 20) with sufficient power (depending on the
application). At full load this means min. 0.8 A for the ME-5820 and min.
1.6 A for the ME-5821.