Operating instructions, Integrated Reverse Osmosis, GiO-Module
Datei:BA_GiO-Modul_9661928_EN_2008-04.docx
9661928
4/14
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
3
Connection / Installation
3.1
Building requirements
•
Conductivity max. 1000μS/cm
•
Water hardness max. 28 °dH
•
Inlet temperature min. 1 °C - max. 35°C (cold water connection)
•
Free of particles > 10 μm
•
Iron < 0.1 mg/l
•
Manganese < 0,04 mg/l
•
Chlorine (free chlorine) < 0.1 mg/l (standard diaphragm)
•
Chlorine (free c
hlorine) ≥ 0.1 to ≤ 2.0 mg/l (chlorine resistant diaphragm)
•
Potassium permanganate < 10 mg/l
•
Silicic acid < 10 mg/l
•
When using GiO modules, mains isolation in accordance with EN1717 is to be assured
NOTE
Please note:
As of a water hardness of 18°dH, please use the en-
closed blue throttle (9715289).
Throttle (9715289)
9743334
Please note:
- Check the on-site drain piping and clean if necessary
- Flush the diaphragm set for 5 minutes
- Perform measurements and document in the commissioning protocol