Operating instructions, Integrated Reverse Osmosis, GiO-Module 

 
 

 

Datei:BA_GiO-Modul_9661928_EN_2008-04.docx 

 

9661928

 

12/14 

W e reserv e the right to c hange ex ec ution and constr uction!  

MEIKO Maschinenbau GmbH & Co. KG,  Englerstr. 3,  D-77652 Offenburg,  Tel.: +49/781/203-0,  Fax: +49/781/203-1121 

 

3.7.1  Connection plan - GiO module M-iClean U-Series for the UK 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

 

 

Drain set 

Towards local drain pipe see 

technical sheet 

 

For connection do not use 

more than three 90° bends

 

Connection set  

Untreated water - re-

move 

(Reinforced hose) 

Supply - untreated water 

Drain - concentrate 

Clean water outlet 

Connection's bush 

electrical 

Pedestal enclosed 

(T

ran

s

pa

re

nt

 hos

e)

 

Connection's bush 

electrical 

Machine 

Waste wa-

ter-hose 

Cover connection's hose / electri-

cal cable 

(R

ei

n

for

c

e

d h

os

e

(Black plastic 

hose) 

Non-return valve 

Содержание GiO Module

Страница 1: ...on and construction MEIKO Maschinenbau GmbH Co KG Englerstr 3 D 77652 Offenburg Tel 49 781 203 0 Fax 49 781 203 1121 Operating instructions Integrated reverse osmose GiO Module TRANSLATION OF THE ORIG...

Страница 2: ...Installation 4 3 1 Building requirements 4 3 2 GiO with AirConcept 5 3 3 Installation 6 3 4 Circuit function diagram 7 3 4 1 Circuit function diagram option connection BA system separator as per EN 17...

Страница 3: ...203 1121 1 Introduction and general information These operating instructions for the integrated reverse osmosis gio module are a supplement to your dishwasher s operating instructions Only work with...

Страница 4: ...water connection Free of particles 10 m Iron 0 1 mg l Manganese 0 04 mg l Chlorine free chlorine 0 1 mg l standard diaphragm Chlorine free chlorine 0 1 to 2 0 mg l chlorine resistant diaphragm Potassi...

Страница 5: ...we stipulate that a chlorine resistant diaphragm must be used NOTE When replacing the standard diaphragm 9703526 or 9651200 60 for the new chlorine resistant diaphragm 9721935 the filter casing and fi...

Страница 6: ...t not be changed With a standard diaphragm The 10 m filter insert item no 9695683 must be replaced every 6 months 7 filter casing length 178 mm With a chlorine resistant diaphragm The 10 m filter inse...

Страница 7: ...Tel 49 781 203 0 Fax 49 781 203 1121 3 4 Circuit function diagram Drain set Drain concentrate transparent hose Appliance with integrated reverse osmosis GiO Module Waste water pipe of the machine Dra...

Страница 8: ...1 Circuit function diagram option connection BA system separator as per EN 1717 Drain set Drain concentrate Transparent hose Waste water pipe from the machine Drain pump Supply untreated water Reinfo...

Страница 9: ...l FV 40 2 FV40 2G K FV 60 2 TopClean 60 ET8 M OS UPster U 500 M2 UPster U 500G M2 Machine Cover connection s hose electrical cable Drain set Towards local drain pipe see technical sheet For connection...

Страница 10: ...ET 15 M OS DV200 2 FV130 2 FV250 2 DV270 2 UPster H 500 M2 Supply untreated water Drain concentrate Clean water outlet Connection s bush electrical cable Machine Cover connection s hose electrical cab...

Страница 11: ...n GiO Module M iClean U serie Drain set Towards local drain pipe see technical sheet For connection do not use more than three 90 bends Connection set Untreated water re move Reinforced hose Option Co...

Страница 12: ...ction plan GiO module M iClean U Series for the UK Drain set Towards local drain pipe see technical sheet For connection do not use more than three 90 bends Connection set Untreated water re move Rein...

Страница 13: ...must always be connect This is the only way to ensure that the drain line is safely separated from the osmosis module The scope of delivery includes a black plastic hose Always open the water inlet b...

Страница 14: ......

Отзывы: