Table 3-3 Settings represent communication special meaning D element
2. MTC thermostat return the frame with the MCbus communication buffer. Take MTC#1 region as an
example: when D7532 and D7563 become 4, data can be read from MTC, up to 30 D elements can be
read at a time, as shown in the following table.
Table 3-4 D component definitions 1
D elements
Explanation
D elements
Explanation
D7532
4
D7548
0
D7533
CH1 measured value (PV)
D7549
CH1 multi-step current
execution segment
D7534
CH2 measured value (PV)
D7550
CH2 multi-step current
execution segment
D7535
CH3 measured value (PV)
D7551
CH3 multi-step current
execution segment
D7536
CH4 measured value (PV)
D7552
CH4 multi-step current
execution segment
D7537
0
D7553
0
D7538
0
D7554
0
D7539
0
D7555
0
D7540
0
D7556
0
D7541
CH1 heat control output value
D7557
Cool control output status
D7542
CH2 heat control output value
D7558
0
D7543
CH3 heat control output value
D7559
Error status word
D7544
CH4 heat control output value
D7560
Set value range wrong
address
D7545
0
D7561
Cold junction temperature
D7546
0
D7562
0
D7547
0
D7563
4
Read common5
1. The main module defines the frame with the MCbus communication buffer. D component definition is
shown in the table below
Table 3-5 Settings indicate special meaning of communication D element
2. MTC thermostat return the frame with the MCbus communication buffer. Take MTC#1 region as an
example: when D7532 and D7563 become 5, data can be read from MTC, up to 30 D elements can be
read at a time, as shown in the following table.
Table 3-6 D component definitions 1
D7500
D7501
D7502~7530
D7531
MTC module station
number to be read
4
Meaningless
Meaningless
D7500
D7501
D7502~7530
D7531
MTC module station
number to be read
5
Meaningless