POWER/CHARGE CONDITIONS 

 
 

Power  is  provided  by  an  internally  mounted  NI-CAD  battery  pack,  which  can  be  charged  by 
applying a regulated 9V D.C. source to the DC input connector. The 9V source will also provide all 
the power required by the unit, reverting to battery power when the source is removed 

 
 

The  internal  battery  charger  will  complete  a  full  charge  within  4  hours,  the  battery  management 
system  detects  battery  and  ambient  under/over  temperature,  cell  voltage,  fast  charge  time  and 
reverts to trickle charge when limits have been reached.  There are two LED's provided to indicate 
current status, power/trickle 'Charge and Fast Charge'. 

 
 

To  charge  the  4830A  switch  the  power  switch  on  the  unit  to  “1”,  connect  the  power  supply  and 
switch it on. The red “fast charge” and orange “trickle charge” LEDs should both be lit. Once the unit 
is  fully  charged  in  the  red,  “fast  charge”  LED  will  extinguish.  The  orange  “trickle  charge”  LED  will 
remain  lit  indicating  that  the  battery  voltage  is  being  maintained  /  topped  up  by  a  trickle  charge 
current. This configuration is recommended for optimum charging of the unit. 

 
 

A  power  low  warning  shown  on  the  bottom  line  of  the  display  and  can  be  cleared  by  taking  the 
cursor position into the mode area i.e.: Hertz, but the message will be re-displayed in approximately 
1 minute. Failure to charge will result in the unit powering down (display will blank) while retaining 
the units last settings. 

 
2. 

POWER MANAGEMENT 

 
 

The  unit  will  enter  its  'Power  Save'  mode  after  approximately  5  minutes  from  the  last  keyboard 
action.  This  can  be  disabled  by  depressing  the  left  and  right  keys  together,  a  message  will  be 
displayed 'Auto-power down' and on releasing the keys a '*' symbol can be seen in the right-hand 
bottom corner indicating the auto power down function is disabled. 

 
 

NOTE:  In  this  mode  a  significant  reduction  in  battery  operation  times  can  be  experienced,  do  not 
leave unit on when not in use. 

 
 

To enable 'Auto-Power shutdown' depress the left and right keys again on release the '*' symbol will 
be removed, auto-power mode is now enabled. 

 

Содержание ENDEVCO 4830A

Страница 1: ...4830A Accelerometer simulator Instruction manual IM4830A Revision E1...

Страница 2: ...DOCUMENT SUBJECT TO U S EXPORT CONTROLS COMPLIANCE APPROVIAL REQUIRED PRIOR TO DISTRIBUTION IM4830 Page 2...

Страница 3: ...ble Simulator Acceleration Displacement Velocity Tachometer Output signals are provided that simulate voltage mode accelerometers IEPE ISOTRON etc and charge mode accelerometers both single ended and...

Страница 4: ...ED will extinguish The orange trickle charge LED will remain lit indicating that the battery voltage is being maintained topped up by a trickle charge current This configuration is recommended for opt...

Страница 5: ...o increase value or down to decrease value note that the values either side will change when roll over occurs depending on count up or down The cursor has to be returned to right hand area to select a...

Страница 6: ...gnal conditioners The connectors provide the following outputs TACHO Provides a simulated tachometer signal with TTL 5 Volt pulses ICP Provides a millivolt output signal as selected on the panel This...

Страница 7: ...QUIRED PRIOR TO DISTRIBUTION IM4830 Page 7 The rear panel contains the power switch and charger input The LED s labeled F and C indicate fast charge F and trickle charge C The charge mode is selected...

Страница 8: ...DOCUMENT SUBJECT TO U S EXPORT CONTROLS COMPLIANCE APPROVIAL REQUIRED PRIOR TO DISTRIBUTION IM4830 Page 8...

Страница 9: ...DOCUMENT SUBJECT TO U S EXPORT CONTROLS COMPLIANCE APPROVIAL REQUIRED PRIOR TO DISTRIBUTION IM4830 Page 9...

Страница 10: ...DOCUMENT SUBJECT TO U S EXPORT CONTROLS COMPLIANCE APPROVIAL REQUIRED PRIOR TO DISTRIBUTION IM4830 Page 10...

Страница 11: ...the solder joint with shrink tubing 6 Reassemble the case and check for proper operation 8 CALIBRATION AND TESTING Annual calibration is recommended to ensure accuracy and proper performance Calibrati...

Страница 12: ...io settings 1 0 10 0 and 100 0 Limits are 1 Verify Tach Output is 5 Volts peak to peak 8 4 Amplitude Accuracy mV OUTPUT 8 4 1 Connect a true RMS voltmeter and an oscilloscope to the mV output socket S...

Страница 13: ...RT CONTROLS COMPLIANCE APPROVIAL REQUIRED PRIOR TO DISTRIBUTION IM4830 Page 13 444 0 313 96 310 8 317 1 555 0 392 44 388 5 396 4 666 0 470 93 466 2 475 6 777 0 549 42 543 9 554 9 888 0 627 91 621 6 63...

Страница 14: ...TRON ICP Output With the exception of the Tach all other outputs of the 4830A are derived from the mV output To verify their operation suitable calibrated signal conditioners should be used e g for th...

Страница 15: ...8 to 1 02 8 7 Amplitude Accuracy DIFF Charge Output 8 7 1 Connect the DIFF Charge Output to the input of the Model 6634B Signal Conditioner Set the 6634B for Type DIFF Sens 10 00 FS 20 0 Mode g DC pK...

Страница 16: ...ransient power glitches The problem can generally be corrected by doing a Memory Reset as described in item 4 If the problem persists the unit is most likely defective 10 0 TECNICAL SUPPORT For techni...

Отзывы: