background image

G

 SAFETY WARNINGS

Safety warnings must be read and understood before instrument is used.  
The following safety information must be observed to insure maximum 
personal safety during the operation of this instrument:

 

Do not use in wet environments.

 

It is recommended that wherever possible isolate the  

  circuit to be tested while connecting and disconnecting test leads.

 

Test leads and prods must be in good order, clean, and with  

  no broken or cracked insulation.

 

Replacement test lead fuses must be of the correct  

  type and rating.

 

 This instrument must not be used if any part of it is damaged.

 

The unit is for intermittent tests only, it must not be used for  

  continuous monitoring of phase rotation.

 

Warnings and precautions must be read and understood before  

  an instrument is used. They must be observed during the  
  operation of this instrument.

Note: This instrument must only be used by suitably trained and 
competent persons

INTRODUCTION

The Megger PSI410 phase rotation indicator provides rapid indication of cor-
rect phase sequence utilising a three dual coloured sequencing LED display 
and a specific audible tone.
To avoid the display rotating at the supply frequency the unit has been 
designed to provide a slow rotational speed of the display to allow easy 
indication of rotation.

Dual phase colour coding has been adopted for the PSI410 to allow ease 
of use on both Brown / Black / Grey and Red / Yellow / Blue colour coded 
supplies.

The PSI410 also features a triple dual coloured LED display that indicates that 
all three phases are present.

INSTRUCTIONS

As both croc clips and prods are supplied with the unit, select the preferred 
method of the connection and connect to the test leads. The croc clip option 
will allow isolation of the supply during connecting and disconnecting the 
test leads. 
The dual coloured LED display at the top of the PSI410 indicates the state 
of each of the connected phases with a green coloured LED indicating 
the phase is present while a red coloured LED shows a missing phase 
connection. This feature enables a graphic display of a good connection 
when using the test prod option and will indicate a phase which has a 
substantial lower voltage than the other two phases.

Connect the test leads following the circuit’s applicable cable colour code 
and once all three phases are connected observe the direction of rotation 
and colour on the sequencing LED display on the PSI410.

Clockwise rotation is indicated by clockwise rotating green LEDs with a 
continuous tone and counter clockwise rotation has counter clockwise 

Содержание PSI410

Страница 1: ...er Kent CT17 9EN England T 44 0 1 304 502101 F 44 0 1 304 207342 E uksales megger com Megger SARL Z A Du Buisson de la Couldre 23 rue Eugène Henaff 78190 TRAPPES France T 33 0 1 30 16 08 90 F 33 0 1 34 61 23 77 E infos megger com Megger AB Obere Zeil 2 61440 Oberursel Germany T 06171 92987 0 F 06171 92987 19 The company reserves the right to change the specification or design without prior notice ...

Страница 2: ...it has been designed to provide a slow rotational speed of the display to allow easy indication of rotation Dual phase colour coding has been adopted for the PSI410 to allow ease of use on both Brown Black Grey and Red Yellow Blue colour coded supplies The PSI410 also features a triple dual coloured LED display that indicates that all three phases are present INSTRUCTIONS As both croc clips and pr...

Страница 3: ...SPECIFICATIONS Rotation display 3 x red green LEDs Phase connection status indication 3 x red green LEDs Phase present indication 195 to 265 V Audible rotation tone Clockwise rotation continuous tone Counter clockwise warble tone 0 4 s on 0 4 s off Maximum voltage phase to phase 500 V Frequency 50 Hz 1 Phase colour coding L1 Brown Red L2 Black Yellow L3 Grey Blue Power supply Power drawn from a mi...

Страница 4: ...chage à trois LED bicolores et d une tonalité spécifique audible Afin d éviter que l affichage ne commute à la fréquence d entrée l unité a été conçue pour fournir une vitesse de rotation lente de l affichage afin de déterminer facilement la rotation Le codage couleur biphasé a été adopté pour le PSI410 afin de faciliter l utilisation des alimentations à code couleur Marron Noir Gris et Rouge Jaun...

Страница 5: ...ion horaire tonalité continue Rotation antihoraire tonalité intermittente 0 4 s marche 0 4 s arrêt Tension maximum entre phases 500 V Fréquence 50 Hz 1 Codage couleur des phases L1 Marron Rouge L2 Noir Jaune L3 Gris Bleu Alimentation électrique L alimentation électrique est tirée d un minimum de deux phases connectées dans n importe quelle position Température ambiante 5 40 C 80 HR Température de ...

Страница 6: ...r liefert eine rasche Anzeige der korrekten Phasensequenz und verwendet ein dreifaches zweifarbiges Sequenzierungs LED Display und einen spezifischen akustischen Anzeigeton Um zu vermeiden dass sich das Display auf der Versorgungsfrequenz dreht wurde das Gerät mit einer langsamen Display Drehgeschwindigkeit ausgelegt die die Drehungsanzeige erleichtert Der PSI410 verwendet eine Doppelphasen Farbco...

Страница 7: ...der Spannungsversorgung verbunden bleiben SPEZIFIKATIONEN Drehdisplay 3 x rote grüne LEDs Anzeige des Phasenverbindungsstatus 3 x rote grüne LEDs Anzeige des Vorhandenseins der Phase 195 bis 265 V Hörbarer Drehton Drehung im Uhrzeigersinn kontinuierlicher Ton Drehung gegen den Uhrzeigersinn variierender Ton 0 4 Sek ein 0 4 Sek aus Maximale Spannung Phase zu Phase 500 V Frequenz 50 Hz 1 Phasenfarbc...

Страница 8: ...gger PSI410 efectúa una medición rápida de la secuencia correcta de fase por medio de una pantalla de secuencia triple bicolor LED y un aviso sonoro específico Para evitar la rotación en pantalla a la frecuencia de alimentación La unidad ha sido diseñada para ofrecer una velocidad lenta de rotación en pantalla para que la indicación de la rotación sea fácil El código de colores bifase ha sido adop...

Страница 9: ...ojo verde Indicación de estado de conexión de fase Indicación con LEDs 3 x rojo verde de fases presentes de 195 a 265 V Tono sonoro de rotación Rotación a derechas tono continuo A izquierdas tono discontinuo 0 4 s on 0 4 s off Tensión máxima entre fases 500 V Frecuencia 50 Hz 1 Código de color de fase L1 Marrón Rojo L2 Negro Amarillo L3 Gris Azul Fuente de alimentación Corriente obtenida de por lo...

Страница 10: ...rsonen worden gebruikt INLEIDING De Megger PSI410 draaiveldrichting indicator geeft een snelle aflezing van de juiste fasevolgorde weer met 3 knipperende LED s en een specifiek geluidsignaal Om te vermijden dat de display gaat draaien bij de voedingsfrequentie werd hij ontworpen met langzame rotatiesnelheid voor een gemakkelijke aflezing van de rotatie De PSI410 werd uitgerust met een tweefasige k...

Страница 11: ...esloten blijven aan de voeding KENMERKEN Rotatieweergave 3 x rood groene LED s Indicatie van de status faseconnectie 3 x rood groene LED s Aanduiding fase aanwezigheid 195 tot 265 V Hoorbare rotatietoon Rotatie met de klok mee aanhoudende zoemtoon Rotatie tegen de klok in variërende zoemtoon 0 4 sec aan 0 4 sec uit Maximum spanning fase naar fase 500 V Frequentie 50 Hz 1 Kleurcode fase L1 Bruin Ro...