 REPAIR AND WARRANTY

The instrument contains static sensitive devices, and care must be taken in 
handling the printed circuit board. If an instrument’s protection has been 
impaired it should not be used, but sent for repair by suitably trained and 
qualified personnel. The protection is likely to be impaired if for example; it 
shows visible damage; fails to perform the intended measurements; has been 
subjected to prolonged storage under unfavourable conditions, or has been 
subjected to severe transport stresses.

NEW INSTRUMENTS ARE GUARANTEED FOR 1 YEAR FROM THE 

DATE OF PURCHASE BY THE USER.

Note

: Any unauthorized prior repair or adjustment will automatically 

invalidate the Warranty.

INSTRUMENT REPAIR AND SPARE PARTS

For service requirements for Megger Instruments contact:

Megger Limited 

 or 

Megger       

 

 

Archcliffe Road    

 

Valley Forge Corporate Centre 

 

Dover  

 

 

2621 Van Buren Avenue 

 

Kent  CT17 9EN 

 

Norristown PA 19403   

England. 

  U.S.A. 

Tel:  +44 (0) 1304 502 243 

Tel:  +1 610 676 8579   

 

Fax: +44 (0) 1304 207 342  

Fax: +1 610 676 8625      

or an approved repair company.

[email protected]

Returning and Instrument for Repair

If it is necessary to retun an instrument for repair, a Returns Authorisation 
number must first be obtained by contacting one of the addresses shown. 
You will be asked to provide key information, such as the instrument serial 
number and fault reported when the number is issued. This will enable the 
Service Department to prepare in advance for the receipt of your instrument, 
and to provide the best possible service to you.

The Returns Authorisation number should be clearly marked on the outside of 
the product packaging, and on any related correspondence. The instrument 
should be sent, freight paid to the appropriate address. If appropriate a copies 
of the original purchase invoice and of the packing note, should be sent 
simultaneously by airmail to expedite clearance through customs.

For instruments requiring repair outside the warranty period a repair estimate will be 
submitted to the sender, if required, before work on the instrument commences.

Approved Repair Companies

Megger operates fully traceable repair and calibration facilities complemented 
by a network of approved repair and calibration companies, to offer excellent 
in-service care for your Megger products. Megger’s streamlined Returns 
Authorization system ensures your product is expected and enables you to 
track its progress on-line.

Содержание MTB7671

Страница 1: ...M MTB7671 2 Test box User Guide...

Страница 2: ...Safety Legislation requires them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as inadvertent...

Страница 3: ...out supply Fuse Fuse RCD and loop test supply socket Continuity and insulation test select switch Continuity and insulation connection sockets Supply check indicators RCD and loop test select switch...

Страница 4: ...ed and the supply LEDs on the MTB7671 2 will be on To test the RCD plug lightly press the button on the top Test button The red indicator bars should disappear and the supply LEDs on the MTB7671 2 go...

Страница 5: ...this test Record the reading on the record card NOTE If in either of the tests listed above the LEDs fail to light the test instrument under test should be returned for a full calibration 4 3 0 5 Test...

Страница 6: ...reading on the record card 5 2 Voltage load test 500 V Set the continuity and insulation test select switch to 500 V and per form an insulation test with the test instrument set to 500 V output If the...

Страница 7: ...s accuracy Record the reading on the record card 5 5 90 M Test Set the continuity and insulation test select switch to 90 M and perform an insulation check using the tester This connects a 90 M 3 resi...

Страница 8: ...a high current loop test Record the reading on the record card 6 3 Conducting a 180 loop test Set the RCD and loop select switch to Loop 180 and perform a loop test using the tester Check that the lo...

Страница 9: ...I mode and perform the test The test box will trip and disconnect power The Tripped LED will light The trip time should be a nominal 40 ms If the tester fails to indicate a tripped RCD then the tester...

Страница 10: ...ect switch and repeating the tests as described in sections 7 2 to 7 6 NOTE RCD Protection In order to protect the current sense circuit the RCD simulator is protected by a 500 mA fuse If the fuse blo...

Страница 11: ...Pass Fail indication Threshold limits 2 Insulation test voltages 250 V 25 max 500 V 25 max 1 kV 25 max 250 V 25 500 V 25 1 kV 25 Pass Fail indication Threshold limits 2 Insulation test resistances 0 2...

Страница 12: ...2 2 kg EMC In accordance with IEC 61326 1 Operation Safety Meets the requirements of IEC61010 1 Refer to safety warnings supplied Environment Conditions The MTB7671 2 is intended for indoor use only C...

Страница 13: ...is necessary to retun an instrument for repair a Returns Authorisation number must first be obtained by contacting one of the addresses shown You will be asked to provide key information such as the i...

Страница 14: ...SW 2125 Australia T 61 0 2 9659 2005 F 61 0 2 9659 2201 E ausales megger com Megger Limited 110 Milner Avenue Unit 1 Scarborough Ontario M1S 3R2 Canada T 1 416 298 9688 Canada only T 1 416 298 6770 F...

Отзывы: