2-8
Receiver (
CAM
)
The following parameters are specified for the
CAM
version of the receiver:
Parameter
Value
Frequency ranges
• Range 1:
power network
• Range 2:
transmitter
• Range 3:
transmitter
50 Hz / 60 Hz
512 Hz / 640 Hz
32.768 kHz
Sensitivity
50 Hz / 60 Hz
32.768 kHz
512 Hz, 640 Hz
at a depth of 1 m
>7 mA
>5 µA
>100 µA
Depth determination
(not available for
Easyloc Basic
)
•
Depth range
•
Resolution
•
Accuracy (assuming interference-
free signal transmission)
- Range 1:
power network
- Ranges 2 and 3:
transmitter
… of a conductor
… of a probe
0.3 m … 5 m
(12 in … 16 ft)
0.1 m
±20 %
±5 % (up to 2 m),
±20 % (2 m … 5 m)
0.3 m … 7 m
(12 in … 23 ft)
0.1 m
±10 % (up to 2 m)
±20 % (2 m … 7 m)
Transmitter
Easyloc Tx
The following parameters are specified for the
Easyloc Tx
transmitter:
Parameter
Value
Transmitted power
(switchable)
32.768 kHz
8.44 kHz (only
Tx+
)
0.1 W / 0.5 W
0.5 W / 2 W
Frequency
32.768 kHz
Power supply
6 x IEC R20 / D cell / Mono
Operating time
40 hours (for intermittent use with alkaline
batteries, 20 °C)
Temperature range
•
Operation
•
Storage
in accordance with DIN EN 60068-1
-20 °C bis +55 °C
-30 °C bis +70 °C
Weight
1.7 kg
Dimensions (W x H x D)
260 x 255 x 140 mm
Type of protection
Dust and water protected
in accordance with IEC / EN 60529
IP 54
Measurement category
in accordance with IEC / EN 61010-1
CAT II / CAT III 440 V
CAT IV 300 V
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30