2-7
2 Technical data
Receiver (all versions) The following parameters are specified for all Versions of the receiver:
Parameter
Value
Power supply
10 x IEC R6 / AA cell / Mignon
Operating time
40 hours (for intermittent use with alkaline
batteries, 20 °C)
Temperature range
•
Operation
•
Storage
in accordance with IEC / EN 60068-1
-20 °C bis +55 °C
-30 °C bis +70 °C
Weight
2.5 kg
Dimensions (W x H x D)
99 x 660 x 252 mm
Type of protection
Dust and water protected
in accordance with IEC / EN 60529
IP 67 from the lower edge of the receiver
up to the lower edge of the battery
compartment, and IP 56 for all parts
above this delineation
Receiver (
Rx, Rx+
and
Basic
)
The following parameters are specified for the
Rx, Rx+
and the
Basic
version of the
receiver:
Parameter
Value
Frequency ranges
• Range 1:
radio
•
Range 2:
power network
• Range 3:
transmitter
15 kHz to 23 kHz
50 Hz / 60 Hz
100 Hz / 120 Hz (only
Rx +
)
32.768 kHz
8.44 kHz (only
Rx +
)
Sensitivity
• Range 1:
radio
•
Range 2:
power network
• Range 3:
transmitter
at a depth of 1 m
>20 µA
>7 mA
>5 µA (at 32.768 kHz)
>40 µA (bei 8.44 kHz)
Depth determination
(not available for
Easyloc Basic
)
•
Depth range
•
Resolution
•
Accuracy (assuming interference-free
signal transmission)
- Range 1:
radio
- Range 2:
power network
- Range 3:
transmitter
… of a conductor
… of a probe
0.3 m … 5 m
(12 in … 16 ft)
0.1 m
±20 %
±20 %
±5 % (up to 2 m),
±20 % (2 m … 5 m)
0.3 m … 7 m
(12 in … 23 ft)
0.1 m
±10 % (up to 2 m)
±20 % (2 m … 7 m)
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30