PID Settings
Operating modes:
-Off : Channel is offline
-Standalone curve 1 & 2: Controller is in
standalone mode and will use throttle
curve 1 or 2 to map the opening of the
DBW throttlebody to the accelerator
pedal position.
-MS Can: Controller will receive the
DBW throttlebody opening request from
CAN-bus. The next setting below is
what will the controller do if the
CAN-bus message is not received for
any reason. Selectable options are “off”
or one of the throttle curves.
Throttlebody specific
settings:
-Throttle PWM Frequency: This setting
selects the operating frequnecy. Range
is from 750Hz to 20000Hz. The
H-Bridge works at better efficiency if a
lower frequency is selected, but there
will be an audible noise from the DBW
throttlebody.
Throttle motor max dytycycle: This
setting can be used to limit the
maximum current that the DBW motor
can take. Usually left at 100%
Throttle sensor max difference: This
setting tells the controller at what
15