Understanding fault codes
ARM Fault codes
Fault code system was added to aid in fault finding. It is
important to understand what causes a particular error
condition in the controller.
BOD error: This is a CPU error that is caused by a low
voltage condition to reset the cpu. Causes include
external error on 5V reference voltage output and internal
power supply failure.
WDT error: This is a CPU error. The CPU has taken too
long to do a task and that has triggered the internal
watchdog timer. The firmwares are tested and it is not
normal to see this error.
Input voltage error: This warning is tripped if the input
voltage goes momentarily below 11 volts. This is an aid to
the installer to check the wiring to the controller if this
warning is shown.
Pedal main and secondary sensor error: This error is
triggered if the input voltage from the accelerator pedal sensor is out of calibrated specification.
Pedal sync error: This error is triggered if the calculated percentage values from main and
secondary sensors differ by a user set amount. This is only done in “linear” throttle calibration
mode. If the “table” calibration is done this error is set if the secondary sensor voltage differs
from the value read from the table.
DBW sensor errors are exactly same as pedal errors.
DBW tracking error: If the DBW actual position does differ too much from the target position this
error is set.
13