6
Main Power Connection
Caution!
1. Do not connect fixture to a dimmer system.
2. This unit must be earthed. (electronically grounded)
3. Replace fuse only with the specified type and rating.
4. Power link maximum 6 units at 110V
The occupation of the connection-cable is as follows:
This device is equipped with a auto switching power supply that will allow you to work from
Caution!
At the last fixture the DMX signal needs to be terminated with a terminator. Solder a
120 Ohm resistor between the (-) and the (+) signal into a 5 pin XLR plug and plug it
in to the last fixture on the signal run. Pre-manufactured terminator plugs are availa-
ble for purchase from your Mega-Lite dealer (P-DMX-T).
L
L
110V
Connection
220V
Connection
N
L
Cable (USA)
Cable (EU)
Pin
110V
Black
Brown
White
Green
Light Blue
Yellow/Green
Live
Neutral
Ground
L
N
220V
L
L
DMX-512 Connection
The fixture is equipped with 5 pin XLR Sockets for DMX input and output. The sockets are wired in parallel. Only use a
shielded twisted pair cable designed for RS-485 and 5 pin XLR plugs and connectors in order to connect the controller
with the fixture or the fixture with another.
DMX—Input
DMX—Output
1. Shield
2. Signal (-)
3. Signal (+)
4. N/A
5. N/A
5
3
4
2
1
1
2
3
4
5
Содержание 7060VW2
Страница 2: ......
Страница 5: ...5 Photometrics All LED s ON WW Only CW Only...