2 STEP DOOR UNLOCK WIRE CONNECTION FOR
5 WIRE ALTERNATING DOOR LOCKS 

+12V

Cut the Existing

Lock Wire

Green / White   

Blue / Red   

Green / Red   

Cut Existing Unlock 

Blue / White 

Cut the Unlock Wire 

Lock

Unlock 

OEM Door Master Lock 

OEM Slave
Door Lock
Switch

+12V

 

Lock

Unlock 

To All Other
Door Lock
Motors

LT. Green / 
Black Wire 

OEM 
Door Lock 
Motor 

Blue / Yellow   

Green / Yellow   

+ 12V

+ 12V 

85 

86 

87 

87A 

30 

H4 

6-Pin 
Door 
Lock 
Wire 
Harness 

 

VACUUM OPERATED DOOR LOCKING SYSTEM:

 

TYPICAL OF MERCEDES BENZ AND AUDI. 

Locate the wire under the driver's kick panel. Use the
voltmeter connecting to ground, verify that you have th
correct wire with the doors unlocked, the voltmeter will
receive "12 volts". Lock the doors and the voltmeter wi
read "0 volt". Move the alligator clip to +12V and the 
voltmeter will receive "12 volts". Cut this wire and mak
connections. Be sure to program door lock timer to   
3.5 seconds. (See Feuture 

II – 1

 Programming.)

 

 
 
 

 

2 STEP DOOR UNLOCK WIRE CONNECTION FOR 
GROUND SWITCHED DOOR LOCKS

 

Cut Existing Unlock 

Lock

Unlock

OEM Door Master Lock Switch 

To All Other 
Door Lock 
Motor

LT. Green / Black 
Wire 

OEM 
Door Lock 
Motor 

Blue / White   

Green / White 

 

Green / Yellow   

Existing 
Lock Wire

Existing 
Unlock Wire

 

H4 

6-Pin 
Door 
Lock 
Wire 
Harness 

Blue / Red   

Blue / Yellow 

 

+12V

 

OEM Door 
Lock Relay 

 

2 STEP DOOR UNLOCK WIRE CONNECTION FOR
POSITIVE SWITCHED DOOR LOCKS 

Cut Existing Unlock 

X

Lock

Unlock 

OEM Door Master Lock 

To All Other
Door Lock
Motors

LT. Green / 
Black Wire

 

OEM Driver's
Door Lock
Motor

+ 12V

 

Blue / Red 

Existing Pos.
Lock Wire

Existing Pos. 
Unlock Wire 

30

87A

87

86

85

+12V

Blue / White   

Green / White   

Green / Yellow   

Blue / Yellow   

+ 12V

OEM Door 
Lock Relay

 

H4 

6-Pin 
Door 
Lock 
Wire 
Harness 

 

 

PROGRAMMING  

A. THE TRANSMITTERS: 

Note:

 This mode will only retain the last 4 remote transmitters programmed. If the transmitter memory is 

exceeded, the security system will start deleting transmitters from the memory in chronological order. 
1. Turn the Ignition switch ‘OFF/ON’ 3 TIMES and stay in the ON position. Within 15 seconds. 

2. Push the Valet switch 

3

 times and holding in on 

3rd 

push until a long chirp is heard. Then release the 

valet switch. You are now in the Transmitter programming mode. 

3. Press and hold any button of the transmitter until the siren responds with a confirming chirp, indicating 

the signal has been stored into memory. 

4. If you have additional transmitters (up to 4) that need to be programmed, repeat step 3 for each 

transmitter. 

Exit:

 

Turn Ignition to 'OFF' position, or leave it for 15 seconds. 3 long chirps & 3 parking light flashes will 

confirm transmitter programming exit. 
 
 
 

MEGA 2550 INSTALL 

7

Содержание MEGA 2550

Страница 1: ...MEGA 2550 2 WAY LCD PAGER ALARM Installation Manual MEGATRONIX CHATSWORTH CA USA MEGA 2550 INSTALL 1...

Страница 2: ...MEGA 2550 INSTALL 2...

Страница 3: ...cle Frame 2 White Wire Parking Light Relay Output 1 Red White Wire Parking Light Relay Power Input 3A Fuse 10A Fuse H8 13 PIN MINI CONNECTOR WIRE HARNESS 4 Green Wire Zone 3 Negative Door Pin Trigger...

Страница 4: ...evice It is a transistorized low current output and should only be connected to the low current positive output from the vehicle s horn switch H1 5 Red wire System Power 12V Constant The RED wire supp...

Страница 5: ...key switch to the RED wire pin 30 of the relay and connect the starter wire to the WHITE wire pin 87a of the relay e Connect the ORANGE Wire from the control module to the ORANGE wire pin 86 of the r...

Страница 6: ...r the same duration as the siren H4 6 PIN DOOR LOCK HARNESS Blue White Wire 30 Door Unlock Relay Blue Red Wire 87a Door Unlock Relay Blue Yellow Wire 87 Door Unlock Relay Green Red Wire 87a Door Lock...

Страница 7: ...e H4 6 Pin Door Lock Wire Harness Blue Red Blue Yellow 12V OEM Door Lock Relay 2 STEP DOOR UNLOCK WIRE CONNECTION FOR POSITIVE SWITCHED DOOR LOCKS Cut Existing Unlock X Lock Unlock OEM Door Master Loc...

Страница 8: ...1 Turn the Ignition switch ON OFF 3 TIMES and stay in the OFF position 2 Push the Valet switch 4 times and hold it on the 4th push until two chirps with a long chirp is heard Then release the valet sw...

Страница 9: ...and 2 minutes Exit Turn Ignition to the ON position or leave it for 15 seconds 3 long chirps will confirm exit Channel 3 4 Timer Control Output Programming 1 Turn the Ignition switch ON OFF 3 TIMES a...

Страница 10: ...itch to the OFF position If the new password code were accepted the unit would report the newly entered code by flashing the LED first indicating the first digit code has been memorized pause and then...

Страница 11: ...se the transmitter button again 2 LED flash 2 siren horn chirps to indicate you are in shock sensor connected to H2 4 pin plug test mode 1 Activate the warn away first stage optional sensor The system...

Страница 12: ...MEGA 2550 INSTALL 12...