T&P Relief Valve Insulation
A set of insulating components is supplied with the Megaflo Eco SolaReady water heater and should be installed to gain
maximum heat and energy saving benefits. See Figure 8 (below), for installation instructions.
Warnings
Under no circumstances should the factory fitted Temperature /Pressure Relief Valve be removed other than by authorised
Heatrae Sadia personnel. To do so will invalidate any guarantee or claim.
The Cold Water Inlet Control kit must be fitted to the mains water supply to the Megaflo Eco SolaReady unit.
No control or safety valves should be tampered with.
Water may drip from the discharge pipe of the pressure relief device (Expansion Valve) and this pipe must be left open to
atmosphere. The discharge pipe should not be blocked or used for any other purpose.
The discharge connections from the Pressure Relief (Expansion) Valve and the Temperature & Pressure Relief Valve must not
be used for any other purposes.
Electrical connections and components should not be placed where they could be splashed in the event of a malfunction,
i.e. away from any discharge pipe, the tundish and various valve and pipe connections.
IMPORTANT INFORMATION:
HOW TO INSULATE YOUR T&P RELIEF VALVE
TO SAVE HEAT AND ENERGY A SET OF INSULATING PARTS FOR
THE T&P RELIEF VALVE HAVE BEEN SUPPLIED WITH THIS WATER
HEATER. INSTALL THE HEATER FIRST THEN FIT THE INSULATING
PARTS BY FOLLOWING THE DIAGRAMS BELOW.
A
B
C
D
T&P RELIEF
VALVE
DISCHARGE
PIPEWORK
TUNDISH
LEFT HAND
INSULATING PIECE
PLASTIC COVER
DISCHARGE PIPE
RIGHT HAND
INSULATING PIECE
CLIP INTO
PLACE !
Figure 8 – Installation of T&P insulation set