background image

 

Warning Threshold Values 

 

Time out after loss of connection

 

Send warning alarm when NetAgent

A

 and UPS lost connection at this configured time 

Critical Load(%)

 

When loading reaches at this % configured, NetAgent

A

 will send warning alarm   

UPS Temperature (

)

 

When UPS temperature reaches at this degree configured, NetAgent

A

 will send warning 

alarm   

Critical Capacity (%)

 

When  UPS  battery  capacity  reaches  at  this  %  configured,  NetAgent

A

  will  send  warning 

alarm     

 

 

 
 

 

Configuration > UPS On/Off Schedule 

 

UPS Action 

When selected event happens at configured time range, UPS will be shut down     

 

 

 

Содержание NetAgentA

Страница 1: ...NetAgentA UPS SNMP Agent User s Manual...

Страница 2: ...right 2018 Mega System Technologies Inc All rights reserved Reproduction without permission is prohibited Technical Support and Contact Information Mega System Technologies Inc Tel 886 2 87922060 Fax...

Страница 3: ...Status 21 Information System Status 21 Information Remote Control 23 Information SMS Modem Status 24 Information NetFeeler 24 Configuration UPS Configuration 24 Configuration UPS On Off Schedule 26 Co...

Страница 4: ...Management File Manager 61 Management Serial Port Debug 61 Management Help 62 Management About 62...

Страница 5: ...re to allow the user to configure IP address central monitoring and multi shutdown on different operating systems Other advance configurations could be accomplished in the Web browser Features 1 Provi...

Страница 6: ...rovides Shutdown Utilities When a computer install our shutdown software in the network that connects to the NetAgentA when UPS is in AC failure condition or Battery Low condition the software would c...

Страница 7: ...NetAgentAA Mini SNMP Card 2 NetAgentA Utility CD 3 Quick Installation Guide Optional 4 M2509 Cable USB v v v v v DA807 1 NetAgentAA Mini SNMP Card 2 NetAgentA Utility CD 3 Quick Installation Guide Opt...

Страница 8: ...9 Status On Off Operating Stop Working D5 D4 Green Blue Power Communication On Off Flashing Normal No Power Sending Receiving Data Status Power On Lost Communication Writing Firmware Yellow On On Off...

Страница 9: ...lation If the PC does not executes CD program automatically please select from File Managment Netility Configure and Search NetAgentA Refer to 4 3 ClientMate Shutdown OS Software Refer to Chapter 6 SM...

Страница 10: ...Login Procedure HTTP HTTPS SSH TELNET 1 Connect NetAgentA to modem router 5 Double click NetAgentA from Netility 5 Enter IP address of the NetAgentA on browser 5 Login via HyperTerminal 2 Install Net...

Страница 11: ...it This helps to identify the card information on Netility NOTE 2 NetAgentA with LCD display may obtain the IP info from it Example of LCD display format as below 7 Enter other parameter on NetAgentA...

Страница 12: ...When NetAgentA IP is known enter such IP address on the browser to login If non LCD NetAgentA model install Netility software to find and configure its IP address...

Страница 13: ...e user to search all the available NetAgentA within network as well as to configure IP address and firmware upgrade Mount the NetAgentA Utility CD on CD ROM and click on Program Installation Netility...

Страница 14: ...ded into 2 sections 1 Online NetAgentA List 2 Function Selection 2 Function 2 1 Launch Web User Interface 2 2 Network Settings 2 3 Firmware Upgrade 2 4 About 2 5 Refresh List 1 2 Individual NetAgentA...

Страница 15: ...he available online NetAegntA within the network with its serial number IP address MAC address Double click on the specific NetAgentA with valid IP address it will direct to the NetAgentA s webpage Li...

Страница 16: ...AgentA the bottom column shows its hardware firmware version and MAC address It also shows the total NetAgentA number that found by Netility and selected Click on NetAgentA Hardware Version Firmware V...

Страница 17: ...nterface Select specific NetAgentA from the list and click on Launch Web User Interface to login to the NetAgentA s webpage 1 Click on NetAgentA 2 Click on Launch Web User Interface Login to the webpa...

Страница 18: ...require to enter the full IP address with port number in order to login For example HTTP port number change to 81 The full address to be enter on browser should be http X X X X 81 X X X X is the IP ad...

Страница 19: ...Default port for each protocol Enter password Once password is enabled and configured it is required to enter the correct password when change any setting or firmware upgrade...

Страница 20: ...from the list then press and hold on SHIFT key as well as click on the last unit of the NetAgentA This is if all NetAgentA from the list are same model If any failure during firmware upgrading please...

Страница 21: ...t Netility verison 2 5 Refresh List The list on Netility would refresh every 2 minutes automatically however manual refresh is also possible by clicking Refresh List Click on Refresh List Searching Li...

Страница 22: ...is page is to show the current UPS connection status in graphic mode with Voltage Frequency and other information Information System Status System Information Here shows all the basic information of t...

Страница 23: ...age shows UPS information Battery Information Rating Information The data is obtained from the reply of UPS or the settings from UPS Configuration webpage Information System Status Network Status This...

Страница 24: ...show Wireless connection status and information when NetAgentA communicates via the compatible WiFi dongle Information Remote Control User can perform several tests to the UPS remotely Once the option...

Страница 25: ...d UPS select the compatible protocol which your UPS supported from the list Wrong protocol selected would cause no communication at all Megatec is default protocol Number of Batteries Enter the number...

Страница 26: ...2 Weeks Month Quarter UPS can be selected Start Time of UPS Test hh mm To enter the time to begin the test UPS Test Type Test option can be select from the drop down list UPS Data Log To enter the tim...

Страница 27: ...this configured NetAgentA will send warning alarm UPS Temperature When UPS temperature reaches at this degree configured NetAgentA will send warning alarm Critical Capacity When UPS battery capacity r...

Страница 28: ...iled then select shutdown Host 1 press on Add The action will be add in the list Then the same for Host 2 select event of AC Power Failed and select shutdown Host 2 from the list and press on Add to b...

Страница 29: ...to turn on off the UPS on particular days The settings here override the settings in Weekly Schedule Warning will be initiated X_ before Schedule shutdown event NetAgentA will send a warning message...

Страница 30: ...igure as Enabled under BIOS Enter the IP address of that PC and system would search its IP accordingly Configuration Network This page is to set NetAgentA s Network settings IPv4 NetAgentA and DNS IP...

Страница 31: ...Type This section is to set communication speed between NetAgentA and Network Once click on Apply NetAgentA will reboot Stop UPS communication when Ethernet disconnected This section is to set if to s...

Страница 32: ...select from the list Domain Name This is the Domain Name you have created from the above selected DDNS provider Login Name This is the Login Account name that you have created with the selected DDNS p...

Страница 33: ...e Domain Name and Login Name will automatically be fill in with serial number of the device Enter the password of the NetAgentA which is printed on the NetAgentA label then click Apply 2 If using rout...

Страница 34: ...3 After 20 minutes NetAgentA should be login with its DDNS Domain name 4 To change domain name or password please go to www icv99 net New Domain name Enter new password Enter email Click on Done...

Страница 35: ...rectly using your xDSL modem by PPPoE Enter the Login name and password to enable the connection Once set up NetAgentA will connect directly to the Internet any abnormal connection failure would also...

Страница 36: ...Wireless network with compatible USB wireless dongle Login to the Wireless Router 1 SSID Name it any 2 Authorization Select WPA2 Personal 3 WPAEncryption AES 4 WPA PSKKey Enter any password 8 63 digi...

Страница 37: ...button on Tamio dongle for 2 3 seconds until the yellow LED begins to flashing WPS Setting for the wireless router When yellow LED of the NetAgentA is flashing open up WPS setting page of the wireles...

Страница 38: ...Start WPS Connection Process When WPS connection successfully the yellow LED on NetAgentAA stop flashing...

Страница 39: ...to find this wireless NetAgentA 2 Login to NetAgentA s webpage under Configuration Wireless Lan webpage it shows the wireless signal With distance of 6 10 meters Router RT AC53 still shows with full s...

Страница 40: ...Configuration SNMP This page is to configure NetAgentA SNMP settings to be used by NMS Network Management System e g SNMPView it is available on the NetAgentA Utility CD...

Страница 41: ...tA receive and send SNMP command Default is 161 Trap Receive Port The port to receive trap Default is 162 SNMPv3 Engine ID SNMPv3 Engine ID Format Type When using SNMPv3 NetAgentA requires to have its...

Страница 42: ...et authorities of administrators Options are Read Read Write and No Access Description This is to make note for administrator s reference Trap Notification Trap Notification Destination IP Address To...

Страница 43: ...on Select to show the full Events List Click on Test to send test trap to ensure all setting is correct Send Power Restore and Adaptor Restore Traps for X time s in X second s Interval This is to set...

Страница 44: ...server Email Port Email Port that use for sending email Enable SSL on Email Transmission Select SSL type for email transmission Sender s Email Address To enter the email address that for sending emai...

Страница 45: ...mail for Event Log To received email notification To set email addresses to receive warning email sent by NetAgentA when selected event occurs It is valid for up to 8 Email addresses Test Email Receiv...

Страница 46: ...ows Short Message Signals SMS to be sent and received using a GSM GPRS CDMA Modem Operation information are as below for single and three ports of NetAgentA SMS Setting Send SMS When Event Occurs Disa...

Страница 47: ...o send SMS enter the port number that SMS Server uses for sending SMS Port 80 is default Account Name If select to use Remote Service to send SMS enter SMS Server s account name if required Password I...

Страница 48: ...th up to 8 users Also to enable disable specific port for HTTP HTTPS Telnet SSH and FTP HTTP HTTPS Enter specific port number to access or disable for HTTP HTTP proxy HTTPS HTTP HTTPS Account User Nam...

Страница 49: ...Telnet SSH Telnet SSH Account Same as HTTP account password settings This is to duplicate the same settings from HTTP User Name To set password for NetAgentA Telnet access Password To set password fo...

Страница 50: ...te the same settings from HTTP User Name To set password for NetAgentA FTP access Password To set password for NetAgentA FTP access Permission To set No Access Read Read Write Permission Rule At least...

Страница 51: ...tAgentA will reboot SSL Information This is to upload the SSL certificate When both public key and certificate are uploaded to NetAgentA web server the communication will be encrypted by SSL To commun...

Страница 52: ...to enable RADIUS RADIUS Server Address To enter the IP address of the RADIUS Server Authentication Port RADIUS port number Default is 812 Shared Key Enter the Shared Key between RADIUS Server and cli...

Страница 53: ...utomation and Control Internet Protocol BACnet BACNet Device Configure the device ID and access port number for the NetAgentA when using BACnet for communication Notification Enter the IP address of t...

Страница 54: ...card holder 2 Place the SIM card on the holder and insert into GSM Modem 3 Attach antenna to the modem Modem Led Status 1 If flash every 0 8 seconds Modem initializing please wait If no respond 1 Chec...

Страница 55: ...s required for the SIM card please enter Confirm SIM PIN Retype SIM card PIN When all done click on Apply Modem Information and Status can be check from Information SMS Modem Status Once click on Appl...

Страница 56: ...section is to set the location or name of each sensor Configuration System This page is to set NetAgentA s system time language and configuration Date Time NetAgentA to synchronize with external or in...

Страница 57: ...Language To set the language of NetAgentA web pages When first start login to the webpage of NetAgentA NetAgentA will auto detects the OS language of the PC and shows the same language on its web pag...

Страница 58: ...se this function to restore a cfg configuration that has been saved earlier Click Browse to the location of the file and click Restore Reset to factory default This function will reset all settings to...

Страница 59: ...on the selected date Log Information SMS Log SMS Log It shows SMS record of all mobile number giving the Date Time of the SMS sent and a detailed description of each When reach to the limit it rewrit...

Страница 60: ...c in chart format Logs can be saved in CSV format by clicking on Save The bar on top can be adjusted to check the log status at specific time of the day Data Log It records UPS Input Voltage Output Vo...

Страница 61: ...with its serial number Mac Address Hardware Firmware version and its IP address Double click on the highlighted unit to open the webpage of such device If the NetAgentA is access by WAN IP Netility W...

Страница 62: ...play under Log Information Management Serial Port Debug It shows the communication status between NetAgentA and UPS by Sent and Received columns Debug Information Command can send automatically by Net...

Страница 63: ...UPS Parameters are Debug Mode Port Speed Baud Data Bits Parity and Stop Bits Two encoding formats ASCII or Hexadecimal Management Help This is to help to illustrate each feature option that NetAgentA...

Страница 64: ...ccordingly Or it could upgrade per preset time Update Firmware from FTP Client Select on Enable Download the appropriate firmware version from website http www megatec com tw Unzip the file and known...

Страница 65: ...FTP login 1 Enter username password that configured on Netility 2 Enter command Is to show available firmware bin file 3 Enter put command with bin file directory 4 Once complete enter command quit...

Отзывы: