13
Electrical Installation
The 971IPS requires a grounded 24VDC supply. The 0V line must be connected to
ground. Failure to do so, will result in damage to the bar or the 24V supply.
A grounding post on the bar is provided for this purpose. Meech recommend that, for
certainty, the bar is grounded using this post, in addition to using a grounded 24VDC
supply.
971IPS
220V AC
24V DC
0V
Power Supply
Grounded 0V
Grounding using
ground post
Connection to the 971IPS is via an industrial M8 4 Pin connector. With the following
pin-outs:
2 4
1 3
Male connector on Bar
4 2
3 1
Female connector on Cable
Pin
Colour
Function Specification
1
Brown
24V (21-27V)
2
White
Clean Pin Output Open collector output. V
max
=24V,
I
max
=20mA
3
Blue
0V/ Ground
4
Black
No connection